Purpose:
The purpose of the study was to determine if the ≥ 15 mm threshold currently used to define PIRADS 5 lesions is the optimal size threshold for predicting high likelihood of clinically significant (CS) cancers.
Materials:
Three hundred and fifty-eight lesions that may be changed from category 4 to 5 or vice versa on the basis of the size criterion (category 4: n = 288, category 5: n = 70) from 255 patients were evaluated. Kendall's tau-b statistic accounting for inter-lesion correlation, generalized estimation equation logistic regression, and receiver operating curve analysis evaluated two lesion size-metrics (lesion diameter and relative lesion diameter-defined as lesion diameter/prostate volume) for ability to identify CS (Gleason grade ≥ 3 + 4) cancer at targeted biopsy. Optimal cut-points were identified using the Youden index. Analyses were performed for the whole prostate (WP) and zone-specific sub-cohorts of lesions in the peripheral and transition zones (PZ and TZ).
Results:
Lesion diameter showed a modest correlation with Gleason grade (WP: τB = 0.21, p < 0.0001; PZ: τB = 0.13, p = 0.02; TZ: τB = 0.32, p = 0.001), and association with CS cancer detection (WP: AUC = 0.63, PZ: AUC = 0.59, TZ: AUC = 0.74). Empirically derived thresholds (WP: 14 mm, PZ: 13 mm, TZ: 16 mm) performed similarly to the current ≥ 15 mm standard. Lesion relative lesion diameter improved identification of CS cancers compared to lesion diameter alone (WP: τB = 0.30, PZ: τB = 0.24, TZ: τB = 0.42, all p < 0.0001). AUC also improved for WP and PZ lesions (WP: AUC = 0.70, PZ: AUC = 0.68, and TZ: AUC = 0.74).
Conclusions:
The current ≥ 15 mm diameter threshold is a reasonable delineator of PI-RADS category 4 and category 5 lesions in the absence of extraprostatic extension to predict CS cancers. Additionally, relative lesion diameter can improve identification of CS cancers and may serve as another option for distinguishing category 4 and 5 lesions.
Related Concept Videos
Categories of Equilibrium
One of the categories of equilibrium is collinear equilibrium, which involves forces acting along a straight line. This type of equilibrium requires only one force equation in the direction of the forces, as the other equations are...
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
The Buckingham Pi Theorem
Determination of Pi Terms
The theorem indicates that the...