Serum TIMP1 and TIMP2 concentration in patients with different grades of meningioma

Farhad Mashayekhi1, Alia Saberi2, Sohail Mashayekhi2

  • 1Department of Biology, Faculty of Sciences, University of Guilan, Rasht, Iran.

Abstract

Insights

Serum levels of tissue inhibitors of metalloproteinases (TIMP-1 and TIMP-2) were significantly lower in patients with higher-grade meningiomas. These findings suggest TIMP-1 and TIMP-2 may aid in classifying meningioma grades.

Area of Science:

  • Neuro-oncology
  • Biochemistry
  • Cancer Biology

Background:

  • Meningiomas are common primary brain tumors.
  • Matrix metalloproteinase-9 (MMP-9) promotes cancer invasion.
  • Tissue inhibitors of metalloproteinases (TIMPs) regulate MMPs.

Purpose of the Study:

  • To evaluate serum concentrations of TIMP-1 and TIMP-2 in meningioma patients.
  • To correlate TIMP levels with meningioma grade.

Main Methods:

  • Serum samples from 90 meningioma patients (grades I-III) and 51 healthy controls were analyzed.
  • Total protein concentration (TPC) was measured using Bio-Rad protein assay.
  • TIMP-1 and TIMP-2 levels were quantified using enzyme-linked immunosorbent assay (ELISA).

Main Results:

  • No significant difference in TPC was observed between patients and controls.
  • TIMP-1 and TIMP-2 were detected in all serum samples.
  • A significant decrease in TIMP-1 and TIMP-2 levels was observed with increasing meningioma grade (I to III) compared to controls.

Conclusions:

  • Lower serum expression of TIMP-1 and TIMP-2 correlates with advanced meningioma stages.
  • Serum TIMP-1 and TIMP-2 detection may assist in grading meningiomas.
  • Further research could explore TIMPs as biomarkers for meningioma progression.

Related Concept Videos

Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance01:25

Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance

In healthy individuals, serum creatinine levels remain stable due to a balance between its constant production—primarily from muscle metabolism—and renal excretion. Creatinine is freely filtered by the glomeruli, making it a valuable marker for estimating renal function. When the glomerular filtration rate (GFR) decreases, the kidneys can only eliminate less creatinine, causing serum levels to rise.Serum creatinine concentration is widely used to estimate creatinine clearance...
231
Graded Potential01:19

Graded Potential

Graded potentials are localized fluctuations in the cell membrane's electrical charge, commonly found in the dendrites of neurons. The magnitude of these potential changes depends on the strength of the initiating stimulus. In a membrane at its resting potential, a graded potential signifies a voltage shift either above -70 mV or below -70 mV.
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
7.1K
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration01:28

Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration

Glomerular filtration rate (GFR) can be estimated from serum creatinine using the modification of diet in renal disease (MDRD) formula or the chronic kidney disease–epidemiology collaboration (CKD–EPI) equation. Both methods are widely used in clinical practice to assess kidney function and guide treatment decisions.The MDRD equation does not require weight or height measurements and is normalized to the body surface area of 1.73 m², considered the average adult surface area.
237
Types of Aggregate Grading01:15

Types of Aggregate Grading

Aggregate grading is crucial in economically obtaining a concrete mix with adequate strength, reasonable workability, and minimal segregation. There are four types of aggregate gradation: well-graded, uniformly (or one-sized) graded, gap-graded, and open-graded.
Well-graded aggregates include a complete range of necessary size fractions that fit together to create a dense matrix with minimal voids, represented by a smooth, continuous gradation curve. This type of grading ensures good...
1.5K
Concentration Cells02:41

Concentration Cells

A concentration cell is a type of a  voltaic cell constructed by connecting two almost identical half-cells, both based on the same half-reaction and using the same electrode, differing only in the concentration of one redox species. A concentration cell's potential, therefore, is determined only by the concentration difference of the particular redox species.
Consider the following voltaic cell:
25.9K
Sieve Analysis and Grading Curves01:19

Sieve Analysis and Grading Curves

Sieve analysis is a method used to determine the particle size distribution of aggregate materials. This process involves the following steps:
1.0K