Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
[Successful Echo-guided Deployment of Stent Graft for Intraoperative Retrograde Aortic Dissection and Rupture;Report
Naoki Kanemitsu1, Takehiko Matsuo, Hiroaki Osada
1Department of Cardiovascular Surgery, Mitsubishi Kyoto Hospital, Kyoto, Japan.
Insights
This case study details a successful endovascular repair of a complex thoracoabdominal aortic aneurysm rupture using echoguided stent-grafts. The innovative technique achieved complete hemostasis and excellent patient recovery without complications.
Area of Science:
- Cardiovascular Surgery
- Vascular Endovascular Therapy
- Medical Imaging in Interventions
Background:
- Chronic dissecting thoracoabdominal aneurysms present significant surgical challenges.
- Intraoperative complications like retrograde aortic dissection require immediate and effective management strategies.
Observation:
- An 82-year-old male experienced massive bleeding from the proximal descending aorta post-thoracoabdominal aortic replacement.
- Trans-esophageal echocardiography (TEE) revealed extensive aortic dissection from the clamp site.
Findings:
- Successful hemostasis was achieved using a combination of suture, surgical glue, and a novel echoguided stent-graft insertion.
- Two stent-grafts were accurately positioned using direct echocardiography and TEE, controlling the bleeding.
- Post-operative CT confirmed optimal stent-graft placement and thoracic aorta remodeling.
Implications:
- Echoguided stent-graft insertion offers a viable and effective solution for managing intraoperative aortic rupture during complex aortic repairs.
- This approach minimizes the risk of paraplegia and promotes favorable long-term aortic remodeling.
- The study highlights the critical role of intraoperative imaging in guiding complex endovascular interventions.
Abstract:
We report a case of chronic dissecting thoracoabdominal aneurysm with intraoperative retrograde aortic dissection and rupture at proximal descending aorta, which was successfully treated by echoguided stent-graft insertion. An 82-year old male underwent thoracoabdominal aortic replacement for dilatation of infra-diaphragmatic aorta. Under F-F bypass, his thoracoabdominal aorta was replaced by a Dacron graft with 4-branches. After he weaned from F-F bypass, we found massive bleeding from proximal descending aorta. Trans-esophageal echocardiography (TEE) showed aortic dissection from the clamp site to the distal anastomotic site of the former total arch replacement. We temporary got hemostasis by suture and surgical glue, and anastomosed a 10 mm-graft to the thoracoabdominal main graft as conduit, then inserted and deployed 2 pieces of stent-graft. Direct echo and TEE contributed to the accurate positioning of them. Bleeding was completely controlled. He well recovered without paraplegia. Post-operative computed tomography (CT) showed good positioning and dilatation of the stentgraft and the perfect reverse remodeling of thoracic aorta.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Ecological Succession
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Aortic Regurgitation I: Introduction