OCCUPATIONAL DOSE DURING ADULT INTERVENTIONAL CARDIOLOGY: FIRST VALUES WITH PERSONAL ACTIVE DOSIMETERS IN CHILE
Carlos Ubeda1, Claudio Morales2, Diego Gutiérrez1
1Departamento de Tecnología Médica, Facultad de Ciencias de la Salud, Universidad de Tarapacá, Arica, Chile.
Insights
Medical staff in interventional cardiology received occupational doses measured by digital dosimeters. Physicians absorbed the highest radiation dose, potentially exceeding eye lens limits without proper protection.
Area of Science:
- Medical Physics
- Radiological Protection
- Cardiology
Background:
- Interventional cardiology procedures involve significant radiation exposure for medical staff.
- Accurate occupational dosimetry is crucial for monitoring and managing radiation risks in healthcare settings.
- Digital active personal dosimeters offer real-time dose monitoring capabilities.
Purpose of the Study:
- To report initial occupational dose measurements for medical staff during adult interventional cardiology procedures.
- To assess radiation exposure levels for physicians, nurses, and radiographers using digital dosimetry.
- To compare measured doses against established occupational dose limits.
Main Methods:
- Digital active personal dosimeters were used to measure personal dose equivalent Hp(10).
- Measurements were conducted for physicians, nurses, and radiographers during 59 interventional cardiology procedures.
- Dose values were recorded over the lead apron to assess effective shielding.
Main Results:
- Mean occupational doses (Hp(10)) per procedure were 47.6 μSv for physicians, 6.2 μSv for nurses, and 4.3 μSv for radiographers.
- Physicians received substantially higher doses compared to nurses and radiographers.
- Calculations indicated that physician doses could surpass the new eye lens dose limit without protective measures.
Conclusions:
- Physicians in interventional cardiology face the highest occupational radiation exposure.
- Digital dosimetry provides valuable data for assessing and managing radiation risks in these procedures.
- Adherence to and potential revision of protective strategies are necessary to ensure staff safety, particularly for physicians, to prevent exceeding dose limits.
Abstract:
The objective of this article is to present initial occupational dose values using digital active personal dosimeters for medical staff during adult interventional cardiology procedures in a public hospital in Chile. Personal dose equivalent Hp(10) over the lead apron of physician, nurse and radiographer were measured during 59 procedures. Mean values of occupational dose Hp(10) per procedure were 47.6, 6.2 and 4.3 μSv for physician, nurse and radiographer, respectively. If no protective tools are used, physician dose can exceed the new eye lens dose limit.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions