Ultrasound-guided Botulinum Toxin-A Injections: A Method of Treating Sialorrhea
Published on: November 9, 2016
24.9K
Ultrasound-Guided Injection of Botulinum Toxin for Cricopharyngeal Dysphagia
Yi-Chian Wang1, Shaw-Gang Shyu, Chueh-Hung Wu
1From the Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan (Y-CW, S-GS, C-HW, T-GW); and Supreme Rehabilitation Clinic, Taipei, Taiwan (Y-CW).
Abstract
No abstract available in PubMed .
Related Concept Videos
Directly Acting Muscle Relaxants: Dantrolene and Botulinum Toxin
1.2K
Directly acting muscle relaxants like dantrolene and botulinum toxin (BoNT) have distinct mechanisms and applications. Dantrolene, a hydantoin derivative, acts on the ryanodine receptor (RYR1) in skeletal muscle cells. RYR1 are calcium channels present at the sarcoplasmic reticulum membrane. In response to excitation, they release calcium ions from the sarcoplasmic reticulum to the cytosol. Calcium promotes actin-myosin-mediated contraction of muscles.
The binding of dantrolene to the RYR1...
The binding of dantrolene to the RYR1...
1.2K
Types of Toxins
3.7K
Humans continually engage with an environment rich in potentially harmful chemicals. These are introduced to our bodies through inhalation, ingestion, or skin contact. These chemicals exist in various forms, such as air and environmental pollutants, agricultural chemicals, organic solvents, and heavy metals.
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
3.7K
Ultrasound II: Endoscopic Ultrasound and FibroScan
727
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Endoscopic Ultrasound (EUS):
727
Ultrasound I: Abdominal Ultrasonography
1.8K
Introduction:
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
1.8K
Assessing Blood pressure using a doppler ultrasound
2.6K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.6K
Gas Chromatography: Sample Injection Systems
1.6K
In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
Two primary injection methods are used...
1.6K