Applicability of ISNT Rule Using BMO-MRW to Differentiate Between Healthy and Glaucomatous Eyes
Do Young Park1, Eun Jung Lee, Jong Chul Han
1Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Purpose:
We evaluated the applicability of the ISNT rule using Bruch's membrane opening minimum rim width (BMO-MRW) in healthy eyes and eyes with normal tension glaucoma (NTG).
Materials And Methods:
In total, 124 healthy eyes and 136 NTG eyes were analyzed. Using 2-dimensional disc photographs, neuroretinal rim (NRR) thickness was measured at the superior, inferior, nasal, and temporal sides of the optic disc. Using spectral domain-optical coherence tomography, BMO-MRW was measured at the same regions. We compared the applicability of the ISNT rule in healthy and NTG eyes between these 2 methods. If the NRR was not clearly distinguished on disc photographs, the eye was classified into the "indistinguishable NRR" group and we only tested applicability of the ISNT rule using BMO-MRW.
Results:
The specificity of "violation of the ISNT rule" for the diagnosis of glaucoma was higher when BMO-MRW was used (66.3%) than using disc photographs (42.2%), whereas the sensitivity did not show a significant difference between the 2 methods (91.7% vs. 86.5%). Compared with eyes with distinguishable NRR (179 eyes), eyes with indistinguishable NRR (81 eyes) had higher axial length, more negative refractive error, and higher tilt ratio (P<0.001). The diagnostic ability of "violation of ISNT rule" using BMO-MRW was not significantly different between eyes with indistinguishable NRR and those with distinguishable NRR (P>0.05).
Conclusions:
Application of the ISNT rule using BMO-MRW shows superiority in distinguishing between healthy and glaucomatous optic discs compared with disc photographs. The ISNT rule can be applied using BMO-MRW even when NRR is indistinguishable on disc photographs, such as in myopic tilted discs.