Interphase Fluorescence in situ Hybridization of Bone Marrow Smears of Multiple Myeloma
Published on: April 15, 2022
Minimal Residual Disease Detection by Flow Cytometry in Multiple Myeloma: Why and How?
1Hematopathology Service, Department of Pathology, Memorial Sloan Kettering Cancer Center, New York, NY.
Abstract:
The outlook for myeloma patients has steadily improved with the introduction of newer drug combinations in recent years. Unlike older therapies that largely achieved only modest levels of neoplastic clone reduction, the newer drug combinations have led to deeper suppression of myeloma clones in most patients. Frequently the neoplastic clones become undetectable with traditional disease evaluation approaches. Recent studies using ultrasensitive disease monitoring have demonstrated that patients with disease undetectable by traditional techniques show wide heterogeneity in disease levels varying by several orders of magnitude. Moreover, measurement of the depth of disease suppression even at very low level has emerged as the most powerful prognostication tool in myeloma. Minimal (or measurable) residual disease (MRD) evaluation has also been proposed as a relevant tool in assessment of drug efficacy and in selection of further therapeutic options. In the face of the robust MRD measurement utility data, it has become critical to develop widely applicable disease monitoring techniques that can be applied to more patients in a variety of clinical setting. Both DNA-based and flow cytometry-based approaches have been successfully developed for this purpose achieving sensitivity approaching 1 neoplastic cell in a million. This review article focuses on the theoretical and practical aspects and challenges of deep MRD monitoring in myeloma by flow cytometry. Challenges of flow cytometric disease monitoring in the era of antigen-directed therapy are also discussed.
Related Concept Videos
Flow Cytometry
In...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses
Residual Stresses in Circular Shafts
Residual Stresses in Bending