Related Experiment Video
Updated: Feb 10, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
The Effect of Contact Force in Atrial Radiofrequency Ablation: Electroanatomical, Cardiovascular Magnetic Resonance,
Steven E Williams1, James Harrison1, Henry Chubb1
1Division of Imaging Sciences and Biomedical Imaging, King's College London, London, United Kingdom.
Objectives:
This study sought to determine the effect of contact force (CF) on atrial lesion size, quality, and transmurality by using a chronic porcine model of radiofrequency ablation.
Background:
CF is a major determinant of ventricular lesion formation, but uncertainty exists regarding the most appropriate CF parameters to safely achieve permanent, transmural lesions in the atria.
Methods:
Intercaval linear ablation (30 W, 42°C, 17 ml/min irrigation) was performed in 8 Göttingen minipigs by using a force-sensing catheter with CF >20 g (high force) or <10 g (low force) at alternate ends of the line, separated by an intentional gap. Voltage mapping and cardiovascular magnetic resonance (CMR) imaging were performed pre-ablation, immediately after ablation, and at 2 months' post-procedure. Lesions were sectioned orthogonal to the axis of ablation to assess transmurality.
Results:
Mean CF was 22.6 ± 11.4 g and 7.8 ± 4.0 g in the high and low CF regions. Acute tissue edema was greater with high CF, both caudally (7.0 mm vs. 4.6 mm; p = 0.016) and cranially (6.9 mm vs. 4.6 mm; p = 0.038). There was no difference in chronic lesion size (voltage mapping) or volume (late gadolinium enhancement CMR) between high and low CF regions. There was no difference in scar density (assessed by low-voltage criteria and late gadolinium enhancement signal intensity) or histological transmurality between high and low CF regions.
Conclusions:
Although high CF (>20 g) resulted in more acute tissue edema than low CF (<10 g), chronically there was no difference in lesion size, quality, or transmurality. Appropriate CF targets for atrial ablation may be lower than previously thought.
Related Concept Videos
Magnetic Force
The magnetic force acting on a moving charge...
Magnetic Resonance Imaging
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Atomic Nuclei: Magnetic Resonance
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...