Related Experiment Video
Updated: Feb 10, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Spatial Relationships of Complex Fractionated Atrial Electrograms and Continuous Electrical Activity to
Simon Kochhäuser1, Atul Verma2, Rupin Dalvi3
1Southlake Regional Health Centre, Newmarket, Ontario, Canada; Division of Electrophysiology, Department of Cardiovascular Medicine, University of Münster, Münster, Germany.
Objectives:
This study sought to evaluate the spatial relationships of focal electrical sources (FSs) to complex fractionated atrial electrograms (CFAE) and continuous electrical activity (CEA).
Background:
Fractionated atrial electrograms have been associated with atrial fibrillation (AF) drivers in computational studies and represent ablation targets in the management of persistent AF.
Methods:
We included a subset of 66 patients (age: 63 [56, 67] years, 69% persistent AF) with electroanatomic data from the SELECT AF (Selective complex fractionated atrial electrograms targeting for atrial fibrillation) randomized control trial that compared the efficacy of CFAE with CEA ablation in AF patients undergoing pulmonary vein antral ablation. Focal sources were identified based on bipolar electrogram periodicity and QS unipolar electrogram morphology.
Results:
A total of 77 FSs (median: 1 [1st quartile, 3rd quartile: 1, 2] per patient) were identified most commonly in the pulmonary vein antrum and left atrial appendage. The proportions of FSs inside CFAE and CEA regions were similar (13% vs. 1.3%, respectively; p = 0.13). Focal sources were more likely to be on the border zone of CFAEs than in CEAs (49% vs. 7.8%, respectively; p = 0.012). Following ablation, 53% of patients had ≥1 unablated extrapulmonary vein FS. The median number of unablated FS was higher in patients with AF recurrence post ablation than in patients without (median: 1 [0, 1] vs. 0 [0, 1], respectively; p = 0.026).
Conclusions:
One-half of the FSs detected during AF localized to the border of CFAE areas, whereas most of the FSs were found outside CEA areas. CFAE or CEA ablation leaves a number of FS unablated, which is associated with AF recurrence. These findings suggest that many CFAEs may arise from passive wave propagation, remote from FS, which may limit their therapeutic efficacy in AF substrate modification.
Related Concept Videos
Electric Field of a Continuous Line Charge
In calculations of electric fields, symmetry is of great use. For example, while calculating electric fields of continuous charge distributions.
Consider a line element with a...
Sources and Properties of Electric Charge
Most atoms additionally constitute another fundamental particle, the neutron. It carries no electrical charge. A...
Finding Electric Potential From Electric Field
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Electric Potential Energy in a Uniform Electric Field
Electrical Systems
To derive the transfer function, consider an RLC...

