Related Experiment Video
Updated: Feb 10, 2026

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease
Changtian Li1, Manish Dhyani2, Atul K Bhan3
1Department of Ultrasound, The Southern Building, Chinese People's Liberation Army General Hospital, Beijing, China.
Objectives:
To assess performance of shear wave elastography for evaluation of fibrosis and the histologic stage in patients with autoimmune liver disease (ALD) and to validate previously established advanced fibrosis cutoff values in this cohort.
Methods:
Shear wave elastography was performed on patients with ALD with an Aixplorer ultrasound system (SuperSonic Imagine, Aix-en-Provence, France) using an SC6-1 transducer. The median estimated tissue Young modulus was calculated from sets of 8 to 10 elastograms. A blinded, subspecialty-trained pathologist reviewed biopsy specimens. The METAVIR classification was used to stage liver fibrosis and necroinflammation. Steatosis was graded from 0 to 4+. The Kendall τ-b correlation test was performed to identify the correlation between the estimated tissue Young modulus and fibrosis, steatosis, and the necroinflammatory score. The Spearman correlation test was performed to identify the correlation between the estimated tissue Young modulus and clinical data. The diagnostic performance of shear wave elastography for differentiating METAVIR stage F2 or higher from F0 and F1 fibrosis was evaluated by a receiver operating characteristic (ROC) curve analysis.
Results:
Fifty-one patients with ALD were analyzed. The estimated tissue Young modulus was positively correlated with the fibrosis stage and necroinflammation score (r = 0.386; P < .001; r = 0.338; P = .002, respectively) but not steatosis (r = -0.091; P = .527). Serum aspartate aminotransferase, alanine aminotransferase, and total bilirubin values were positively correlated with the estimated tissue Young modulus (r = 0.501; P < .001; r = 0.44; P = .001; r = 0.291; P = .038). The serum albumin value was negatively correlated (r = -0.309; P = .033). The area under the ROC curve was 0.781 (95% confidence interval, 0.641-0.921) for distinguishing F2 or greater fibrosis from F0 and F1 fibrosis. Based on the ROC curve, an optimal cutoff value of 9.15 kPa was identified (sensitivity, 83.3%; specificity, 72.7%).
Conclusions:
Shear wave elastography is a novel noninvasive adjunct to liver biopsy in evaluation and staging of patients with ALD, showing the potential for serial evaluations of disease progression and treatment responses.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
12:18Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
Related Concept Videos
Diseases of the Liver and Gallbladder
Cirrhosis is characterized by the scarring of hepatic lobules in the liver, which are replaced by fibrous tissue, affecting the liver's normal functioning. NAFLD, on the other hand, is caused by an excessive build-up of fat in the liver, not...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
The Wave Nature of Light
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.