Related Experiment Video
Updated: Feb 10, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
[Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer
Liugang Gao1, Hongfei Sun1, Tao Lin1
1Department of Radiation Oncology, Second People's Hospital of Changzhou, Nanjing Medical University, Changzhou, Jiangsu 213003, P.R.China.
Abstract:
This paper proposes a novel metal artifact reduction (MAR) algorithm for dental implants in kilovoltage computed tomography (kVCT) using megavoltage cone-beam computer tomography (MVCBCT). Firstly, two CT images were derived by scanning patient with dental implants using kVCT and MVCBCT. Metal image was derived by thresholding segmentation in kVCT. MVCBCT and kVCT images were fused to generate prior image which was forward projected to get surrogate sinogram of metal trace. The corrected image was generated by filtered backprojection (FBP) reconstruction in corrected sinogram. The results of proposed algorithm were compared with other frequently-used metal artifact reduction algorithm, such as normalized MAR (NMAR), normalized MAR using MVCBCT prior images (NMAR-MV), and linear interpolation MAR (LIMAR). The normalized root mean square deviation (NRMSD) and mean absolute deviation (MAD) were computed. The experiment showed that the proposed method removed serious metal artifacts without introducing new artifacts. The values of NRMSD and MAD for proposed method were the minimum in all methods. The values of NRMSD for NMAR, NMAR-MV, LIMAR and the proposed method were 21.0%, 22.1%, 41.9% and 17.0% respectively. And MAD values of them were 232, 235, 553, 205 HU, respectively. In conclusion, the proposed metal artifact reduction algorithm can successfully suppress metal artifacts for dental implants, and greatly improve the quality of CT image.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Oxidation-Reduction Reactions
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...