Related Experiment Video
Updated: Feb 10, 2026

Method for Recording Broadband High Resolution Emission Spectra of Laboratory Lightning Arcs
Published on: August 27, 2019
Determination of Hexavalent Chromium Fractions in Plastics Using Laboratory-Based, High-Resolution X-ray Emission
Evan P Jahrman1, Gerald T Seidler1, John R Sieber2
1Physics Department , University of Washington , Seattle , Washington 98195-1560 , United States.
Abstract:
Cr(VI) is a well-known human carcinogen with many water-soluble moieties. Its presence in both natural and man-made substances poses a risk to public health, especially when contamination of groundwater is possible. This has led the European Union and other jurisdictions to include Cr(VI) in restriction of hazardous substances regulations. However, for several important industrial and commercial purposes, analytical capability to characterize Cr(VI) is known to be insufficient for regulatory purposes. For example, advanced X-ray spectroscopies, particularly synchrotron-based X-ray absorption fine structure (XAFS) studies, have shown that species interconversion and under-extraction can be difficult to prevent in many existing liquid extraction protocols when applied to plastics, mining ores and tailings, and paint sludges. Here, we report that wavelength dispersive X-ray fluorescence spectroscopy taken at energy resolutions close to the theoretical limit imposed by the core-hole lifetime, generally called X-ray emission spectroscopy (XES) in the synchrotron community, can be used in the laboratory setting for noninvasive, analytical characterization of the Cr(VI)/Cr ratio in plastics. The selected samples have been part of ongoing efforts by standards development organizations to create improved Cr(VI) testing protocols, and the present work provides a direct proof-of-principle for the use of such extremely high-resolution laboratory WDXRF as an alternative to liquid extraction methods for regulatory compliance testing of Cr(VI) content. As a practical application of this work, we report a value for the Cr(VI) mass fraction of the new NIST Standard Reference Material 2859 Restricted Elements in Polyvinyl Chloride.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
07:55Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering
Published on: April 17, 2018
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Molecular Spectroscopy: Absorption and Emission
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Interference
Atomic Spectroscopy: Absorption, Emission, and Fluorescence