Related Experiment Video
Updated: Feb 10, 2026

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
Improved fracture prediction using different fracture risk assessment tool adjustments in HIV-infected women
Jingyan Yang1, Anjali Sharma2, Qiuhu Shi3
1Department of Epidemiology, Columbia University Mailman School of Public Health, New York.
Objectives:
A fracture risk assessment tool (FRAX) using clinical risk factors (CRFs) alone underestimates fracture risk in HIV-infected men. Our objective was to determine whether accuracy of FRAX would be improved by considering HIV as a cause of secondary osteoporosis, and further improved with addition of dual-energy X-ray absorptiometry parameters in HIV-infected women.
Design:
Subgroup analysis of Women's Interagency HIV Study.
Methods:
We included 1148 women (900 HIV-infected and 248 uninfected) over age 40 with data to approximate FRAX CRFs and 10-year observational data for incident fragility fractures; 181 (20%) HIV-infected women had dual-energy X-ray absorptiometry data. Accuracy of FRAX was evaluated by the observed/estimated ratios of fracture in four models: CRFs alone; CRFs with HIV included as a cause of secondary osteoporosis; CRFs and femoral neck bone mineral density (FN BMD); and CRFs, FN BMD and trabecular bone score.
Results:
FRAX using CRFs were less accurate in HIV-infected than uninfected women for major osteoporotic (observed/estimated ratio: 5.05 vs. 3.26, P < 0.001) and hip fractures (observed/estimated ratio: 19.78 vs. 7.94, P < 0.001), but improved when HIV was included as a cause of secondary osteoporosis. Among HIV-infected women, FRAX accuracy improved further with addition of FN BMD (observed/estimated ratio: 4.00) for hip fractures, but no further with trabecular bone score.
Conclusion:
FRAX using CRFs alone underestimated fracture risk more in older HIV-infected women than otherwise similar uninfected women. Accuracy is improved when including HIV as a cause of secondary osteoporosis for both major osteoporotic and hip fractures, whereas addition of FN BMD only improved accuracy for hip fracture.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
The Anchoring-and-Adjustment Heuristic
Adjusting a Traverse
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Predicting Molecular Geometry