Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
Published on: June 2, 2020
Calibrating an Ionosonde for Ionospheric Attenuation Measurements
Lorenzo Gilli1, Umberto Sciacca2, Enrico Zuccheretti3
1Istituto Nazionale di Geofisica e Vulcanologia, 00143 Rome, Italy. lorenzo.lw89@gmail.com.
This study introduces a new method for measuring ionospheric signal attenuation using precise system calibration. This approach accurately determines absolute signal loss after a single reflection, overcoming limitations of previous techniques.
Area of Science:
- Space Physics
- Atmospheric Science
- Geophysics
Background:
- Vertical ionospheric soundings are common, but signal attenuation is often overlooked.
- Existing methods for absorption measurement have limitations, including unknown ground reflection and inconsistent second reflections.
Purpose of the Study:
- To present a novel method for determining absolute signal attenuation in vertical ionospheric soundings.
- To overcome the limitations of traditional absorption measurement techniques.
Main Methods:
- Precise calibration of the ionospheric sounding system.
- Measurement of absolute signal attenuation after a single reflection.
- Analysis of systematic errors due to antenna calibration imperfections.
Main Results:
- The developed method allows for accurate determination of signal attenuation trends over time.
- Demonstration of the method's capabilities through a set of meaningful measurements.
- Identification of systematic errors inherent in the calibration process.
Conclusions:
- The precise calibration method offers a more accurate way to measure ionospheric signal attenuation.
- This technique is particularly valuable for tracking long-term trends in ionospheric absorption.
- Further research can refine calibration for even greater accuracy.
Related Concept Videos
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...