Optic nerve sheath diameter measured using early unenhanced brain computed tomography shows no correlation with
Dong Hoon Lee1, Sun Hwa Lee2, Je Hyeok Oh1
1Department of Emergency Medicine, Chung-Ang University Hospital, College of Medicine, 102, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea.
Aim:
Previous studies indicated that the optic nerve sheath diameter (ONSD) measured using brain computed tomography (CT) is a prognostic factor for poor neurological outcome after cardiac arrest. However, these studies were retrospective or included a small sample size. We performed a prospective multi-centre observational study to investigate the correlation between the ONSD on early brain CT and neurological outcomes in patients undergoing targeted temperature management (TTM).
Methods:
This study used data from the Korean Hypothermia Network prospective registry between November 2015 and October 2016. Out-of-cardiac arrest patients who underwent brain CT within 2 h after return of spontaneous circulation (ROSC) were included. The primary endpoint was neurological outcomes at 6 months (cerebral performance category; CPC); the secondary outcome was hospital mortality. The ONSD was measured using unenhanced brain CT images.
Results:
In total, 374 patients were included from 18 hospitals, and 329 underwent CT within 2 h after ROSC. Six months after cardiac arrest, good (CPC 1-2) and poor (CPC 3-5) neurological outcomes were observed in 99 (30.09%) and 230 (69.91%) patients, respectively. There was no significant difference in the ONSD between groups (good outcome group: 5.61 ± 0.59 mm, poor outcome group: 5.69 ± 0.79 mm; p = 0.275), nor between discharged patients who survived and those with hospital mortality (5.63 ± 0.64 mm and 5.70 ± 0.67 mm, respectively, p = 0.399).
Conclusion:
The ONSD on initial brain CT after ROSC was not correlated with neurological outcome at 6 months in patients who underwent TTM.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Imaging Studies III: Computed Tomography
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Correlations
Cardiac Catheterization IV: Nursing Management