Related Experiment Video
Updated: Feb 10, 2026

Comparing Objective Conjunctival Hyperemia Grading and the Ocular Surface Disease Index Score in Dry Eye Syndrome During COVID-19
Published on: May 25, 2022
Reliability of a New Symptom Score in a Titrated Quantitative Conjunctival Provocation Test Supported by an Objective
Oliver Pfaar1,2, Dan Philipp Claßen1,2, Anatoli Astvatsatourov3,4
1Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Background:
Allergen provocation tests are useful methods for proving the clinical relevance of an allergen-specific sensitization. Among these methods, the conjunctival provocation test (CPT) represents an easy-to-use tool. However, its readout parameters have not yet been internationally standardized or validated. Photodocumentation has been shown as a good option for objectifying a CPT reaction, supporting the local investigator assessment. Based on test-retest reliability of the score and an objective digital photoanalysis of the conjunctival redness, this study aimed to prove the reproducibility of a new CPT scoring system for use in clinical trials (ClinicalTrials.gov identifier: NCT02690740).
Methods:
A titrated quantitative CPT was conducted outside of the pollen season in a final cohort of 23 adult patients with birch or grass pollen-induced allergic rhinoconjunctivitis. Conjunctival symptoms were analyzed using a standardized symptom score. Conjunctival redness was also evaluated by an external observer and correlated with a digital photoanalysis using MATLAB software.
Results:
A test-retest correlation of 0.6 (p < 0.01) was found for the symptom score results. Likewise, a correlation of 0.65 (p < 0.01) was observed in the digital photoanalysis. The total symptom score showed a decrease in the mean value of 0.48 score points in the retest.
Conclusions:
This study reveals both a valuable test-retest correlation of the proposed score as well as a good correlation of eye redness with the (objective) photodocumentation. Based on our results, we can recommend the use of this scoring system as a valuable clinical protocol for future clinical trials.