A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for
Juanqi Wang1,2, Zhi Chen1,2, Weiwei Li1,2
1Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.
Background:
A new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general multicriteria optimization (MCO) was recommended in the study. The purpose was to combine both benefits of AutoPlanning optimization and MCO (APMCO) for achieving an individual volumetric-modulated arc therapy (VMAT) plan according to the clinically achieved patient-specific tradeoff among conflicting priorities. The preclinical investigation of this optimization approach for nasopharyngeal carcinoma (NPC) radiotherapy was performed and compared to general MCO VMAT.
Methods:
A total of 60 NPC patients with various stages were enrolled in this study. General MCO and APMCO plans were generated for each patient on the treatment planning system. The differences between two planning schemes were evaluated and compared.
Results:
All plans were capable of achieving the prescription requirement. The planning target volume coverage and conformation number were remarkably similar between general MCO and APMCO plans. There were no significant differences in most of organs at risk (OARs) sparing. However, in APMCO plans, relatively remarkable decreases were observed in the mean dose (Dmean) to the glottic larynx and pharyngeal constrictor muscles. The reductions of average Dmean to the two OARs were 10.5% (p < 0.0001) and 8.4% (p < 0.0001), respectively. APMCO technique was found to increase the planning time for an average of approximately 5 h and did not lead to a significant increase of monitor units compared to general MCO.
Conclusions:
The potential of the APMCO strategy is best realized with a clinical implementation that exploits individual generation of Pareto surface representations without manual interaction. It also assists physicians to ensure navigation in a more efficient and straightforward manner.