Real-Time, Automated Detection of Ventilator-Associated Events: Avoiding Missed Detections, Misclassifications, and
Erica S Shenoy1, Eric S Rosenthal2, Yu-Ping Shao3
11Infection Control Unit,Massachusetts General Hospital,Boston,Massachusetts.
Abstract:
OBJECTIVETo validate a system to detect ventilator associated events (VAEs) autonomously and in real time.DESIGNRetrospective review of ventilated patients using a secure informatics platform to identify VAEs (ie, automated surveillance) compared to surveillance by infection control (IC) staff (ie, manual surveillance), including development and validation cohorts.SETTINGThe Massachusetts General Hospital, a tertiary-care academic health center, during January-March 2015 (development cohort) and January-March 2016 (validation cohort).PATIENTSVentilated patients in 4 intensive care units.METHODSThe automated process included (1) analysis of physiologic data to detect increases in positive end-expiratory pressure (PEEP) and fraction of inspired oxygen (FiO2); (2) querying the electronic health record (EHR) for leukopenia or leukocytosis and antibiotic initiation data; and (3) retrieval and interpretation of microbiology reports. The cohorts were evaluated as follows: (1) manual surveillance by IC staff with independent chart review; (2) automated surveillance detection of ventilator-associated condition (VAC), infection-related ventilator-associated complication (IVAC), and possible VAP (PVAP); (3) senior IC staff adjudicated manual surveillance-automated surveillance discordance. Outcomes included sensitivity, specificity, positive predictive value (PPV), and manual surveillance detection errors. Errors detected during the development cohort resulted in algorithm updates applied to the validation cohort.RESULTSIn the development cohort, there were 1,325 admissions, 479 ventilated patients, 2,539 ventilator days, and 47 VAEs. In the validation cohort, there were 1,234 admissions, 431 ventilated patients, 2,604 ventilator days, and 56 VAEs. With manual surveillance, in the development cohort, sensitivity was 40%, specificity was 98%, and PPV was 70%. In the validation cohort, sensitivity was 71%, specificity was 98%, and PPV was 87%. With automated surveillance, in the development cohort, sensitivity was 100%, specificity was 100%, and PPV was 100%. In the validation cohort, sensitivity was 85%, specificity was 99%, and PPV was 100%. Manual surveillance detection errors included missed detections, misclassifications, and false detections.CONCLUSIONSManual surveillance is vulnerable to human error. Automated surveillance is more accurate and more efficient for VAE surveillance.Infect Control Hosp Epidemiol 2018;826-833.
Related Concept Videos
Detection of Gross Error: The Q Test
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...