Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model
Kalpit N Shah1, Gregory Walker1, Sarath C Koruprolu1
1Department of Orthopaedic Surgery, Warren Alpert School of Medicine, Brown University, Providence, RI, USA.
Abstract:
Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti) rods are commonly utilized for spinal fixations, however, theoretically stiffer materials, such as cobalt-chrome (CoCr) rods are also available. Despite ongoing use in clinical practice, there is little biomechanical evidence that compares the construct ability to withstand fatigue stress for Ti and Co-Cr rods. Six models using 2 polyethylene blocks each were used to simulate a pedicle subtraction osteotomy. Within each block 6.0×45 mm polyaxial screws were placed and connected to another block using either two 6.0×100 mm Ti (3 models) or CoCr rods (3 models). The rods were bent to 40° using a French bender and were secured to the screws to give a vertical height of 1.5 cm between the blocks. The blocks were fatigue tested with 700N at 4 Hz until failure. The average number of cycles to failure for the Ti rod models was 12840 while the CoCr rod models failed at a significantly higher, 58351 cycles (P=0.003). All Ti models experienced rod fracture as the mode of failure. Two out of the three CoCr models had rod fractures while the last sample failed via screw fracture at the screw-tulip junction. The risk of rod failure is substantial in the setting of long segment spinal arthrodesis and corrective osteotomy. Efforts to increase the mechanical strength of posterior constructs may reduce the occurrence of this complication. Utilizing CoCr rods in patients with pedicle subtraction osteotomy may reduce the rate of device failure during maturation of the posterior fusion mass and limit the need for supplemental anterior column support.
More Related Videos
06:32Coronoid-Temporalis Pedicled Flap for Orbital Floor Defect Reconstruction
Published on: December 5, 2025
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits