Related Experiment Video
Updated: Feb 10, 2026

The Role of Fabric in Frictional Properties of Phyllosilicate-Rich Tectonic Faults
Published on: November 6, 2021
The Crotone Megalandslide, southern Italy: Architecture, timing and tectonic control
Massimo Zecchin1, Flavio Accaino2, Silvia Ceramicola2
1(OGS) Istituto Nazionale di Oceanografia e di Geofisica Sperimentale, Borgo Grotta Gigante, 42/c, 34010, Sgonico, Trieste, Italy. mzecchin@inogs.it.
Abstract:
Large-scale submarine gravitational land movements involving even more than 1,000 m thick sedimentary successions are known as megalandslides. We prove the existence of large-scale gravitational phenomena off the Crotone Basin, a forearc basin located on the Ionian side of Calabria (southern Italy), by seismic, morpho-bathymetric and well data. Our study reveals that the Crotone Megalandslide started moving between Late Zanclean and Early Piacenzian and was triggered by a contractional tectonic event leading to the basin inversion. Seaward gliding of the megalandslide continued until roughly Late Gelasian, and then resumed since Middle Pleistocene with a modest rate. Interestingly, the onshore part of the basin does not show a gravity-driven deformation comparable to that observed in the marine area, and this peculiar evidence allows some speculations on the origin of the megalandslide.
More Related Videos
06:04Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
08:01Identification of Homologous Recombination Events in Mouse Embryonic Stem Cells Using Southern Blotting and Polymerase Chain Reaction
Published on: November 20, 2018
Related Concept Videos
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Polymer Classification: Architecture
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...