Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Free-breathing ultrashort echo time lung magnetic resonance imaging using stack-of-spirals acquisition: A feasibility
Min Jae Cha1, Hyun Jeong Park1, Mun Young Paek2
1Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
Objectives:
To investigate the diagnostic accuracy of lung magnetic resonance imaging (MRI) with a free-breathing three-dimensional ultrashort echo time spoiled gradient echo sequence using a stack-of-spirals acquisition (spiral 3D UTE) for pulmonary nodule detection at 3 T in oncology patients.
Methods:
The institutional review board approved this retrospective study. Between June and September of 2017, 32 oncology patients underwent both free-breathing spiral 3D UTE of the lungs and thin-section chest computed tomography (CT) for pulmonary metastasis workups. Semiquantitative analyses of the visible pulmonary vessels, bronchi, mediastinum, and overall image quality on spiral 3D UTE were assessed by two reviewers; CT was used as the reference standard. The probability of nodule presence also was assessed.
Results:
The mean acquisition duration of the spiral 3D UTE was 327 s (range, 300-465 s). The pulmonary vessels and bronchi were visible nearly consistently up to the sub-sub-segmental branch levels on spiral 3D UTE (96.9% [31/32] and 90.6% [29/32], respectively). >90% of the spiral 3D UTE images had an acceptable or good mediastinal evaluation; >80% had good or excellent overall image quality. Fifty nodules (6.1 ± 5.9 mm) were identified in 13 patients on CT; the overall nodule detection rate of spiral 3D UTE was 86% (43/50). All 20 nodules ≥ 5 mm in diameter were identified on spiral 3D UTE (100%).
Conclusions:
Free-breathing spiral 3D UTE had high sensitivity for the detection of pulmonary nodules, a reasonable scan duration, and acceptable image quality, which may make it a potential alternative to CT for oncology patients.
More Related Videos
05:07Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Breathing
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Atomic Nuclei: Magnetic Resonance
Lung Capacity