Related Experiment Video
Updated: Feb 10, 2026

Mapping Metabolism: Monitoring Lactate Dehydrogenase Activity Directly in Tissue
Published on: June 21, 2018
Higher Accuracy of the Lactate Minimum Test Compared to Established Threshold Concepts to Determine Maximal Lactate
Patrick Wahl1,2, Lukas Zwingmann1,2, Christian Manunzio2,3
1Department of Molecular and Cellular Sport Medicine, Institute of Cardiovascular Research and Sport Medicine, German Sport University Cologne, Germany.
Abstract:
This study evaluated the accuracy of the lactate minimum test, in comparison to a graded-exercise test and established threshold concepts (OBLA and mDmax) to determine running speed at maximal lactate steady state. Eighteen subjects performed a lactate minimum test, a graded-exercise test (2.4 m·s-1 start,+0.4 m·s-1 every 5 min) and 2 or more constant-speed tests of 30 min to determine running speed at maximal lactate steady state. The lactate minimum test consisted of an initial lactate priming segment, followed by a short recovery phase. Afterwards, the initial load of the subsequent incremental segment was individually determined and was increased by 0.1 m·s-1 every 120 s. Lactate minimum was determined by the lowest measured value (LMabs) and by a third-order polynomial (LMpol). The mean difference to maximal lactate steady state was+0.01±0.14 m·s-1 (LMabs), 0.04±0.15 m·s-1 (LMpol), -0.06±0.31 m·s1 (OBLA) and -0.08±0.21 m·s1 (mDmax). The intraclass correlation coefficient (ICC) between running velocity at maximal lactate steady state and LMabs was highest (ICC=0.964), followed by LMpol (ICC=0.956), mDmax (ICC=0.916) and OBLA (ICC=0.885). Due to the higher accuracy of the lactate minimum test to determine maximal lactate steady state compared to OBLA and mDmax, we suggest the lactate minimum test as a valid and meaningful concept to estimate running velocity at maximal lactate steady state in a single session for moderately up to well-trained athletes.
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Self-Concept
Infancy and Emerging Recognition
During infancy, self-concept is virtually nonexistent. Babies do not distinguish themselves as separate entities and often mistake their...
Wald-Wolfowitz Runs Test II
For binary data, runs are identified using symbols such as + and −, or equivalently, 1s and 0s. In...
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...

