Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Cleaning, Sterilization, and Disinfection01:30

Cleaning, Sterilization, and Disinfection

10.5K
Cleaning, disinfection, and sterilization are the methods that help to break the infection chain and prevent disease.
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
10.5K
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

9.2K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
9.2K
Methods of Sterilization I: Physical Methods01:29

Methods of Sterilization I: Physical Methods

23.7K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
23.7K
Range Rule of Thumb to Interpret Standard Deviation01:13

Range Rule of Thumb to Interpret Standard Deviation

13.7K
The range rule of thumb in statistics helps us calculate a dataset's minimum and maximum values with known standard deviation. This rule is based on the concept that 95% of all values in a dataset lie within two standard deviations from the mean.
For instance, the range rule of thumb can be used to find the tallest and the shortest student in a class, given the mean student height and standard deviation. If the mean student height is 1.6 m and the standard deviation, s is 0.05 m, the height...
13.7K
Data Reporting and Recording01:24

Data Reporting and Recording

5.5K
Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.5K
Types of Reports I: Hands-off Report01:25

Types of Reports I: Hands-off Report

1.5K
A hand-off report, also known as a change-of-shift report, is a crucial nursing process that ensures the smooth transition of patient care responsibilities between nursing staff.
Following are the key components and categories of hand-off reports:
Purpose and Process:
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Using Hologram-Based Augmented Reality in Anatomy Learning: The TEACHANATOMY Randomized Trial.

Academic medicine : journal of the Association of American Medical Colleges·2025
Same author

Iatrogenic nerve injury in primary and revision reverse total shoulder arthroplasty.

Archives of orthopaedic and trauma surgery·2022
Same author

Treatment outcomes of patients with Cutibacterium acnes-positive cultures during total joint replacement revision surgery: a minimum 2-year follow-up.

Archives of orthopaedic and trauma surgery·2022
Same author

Feasibility of ultrasound-based measurement of dorsal scaphoid displacement: A 3D-model study.

Hand surgery & rehabilitation·2021
Same author

Triquetrum osteotomy to approach an otherwise inaccessible coronal malunion of the hamate.

Hand surgery & rehabilitation·2021
Same author

Primarily conservative treatment for triple (A2-A3-A4) finger flexor tendon pulley disruption.

Hand surgery & rehabilitation·2021

Related Experiment Video

Updated: Feb 10, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
06:50

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb

Published on: December 2, 2017

9.6K

Continuing to work with a sterile thumb splint: A case report.

S Roner1, P Fürnstahl1, A Schweizer2

  • 1Computer Assisted Research and Development Group, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.

Hand Surgery & Rehabilitation
|May 22, 2018
PubMed
Summary

This study introduces a novel, reusable splint for immobilizing the metacarpophalangeal (MCP) joint in orthopedic surgeons with skier's thumb. This allows them to continue surgical procedures in a sterile environment.

Keywords:
Articulation métacarpo-phalangienneAttelle réutilisableAttelle stérileConservateurLigament collatéral ulnaireMetacarpophalangeal jointNonoperativePouce du skieurReusable splintSkier's thumbSterile splintUlnar collateral ligament

More Related Videos

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
08:17

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts

Published on: April 14, 2023

1.2K
Imaging Mycobacterium tuberculosis in Mice with Reporter Enzyme Fluorescence
10:06

Imaging Mycobacterium tuberculosis in Mice with Reporter Enzyme Fluorescence

Published on: February 26, 2018

7.8K

Related Experiment Videos

Last Updated: Feb 10, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
06:50

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb

Published on: December 2, 2017

9.6K
Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
08:17

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts

Published on: April 14, 2023

1.2K
Imaging Mycobacterium tuberculosis in Mice with Reporter Enzyme Fluorescence
10:06

Imaging Mycobacterium tuberculosis in Mice with Reporter Enzyme Fluorescence

Published on: February 26, 2018

7.8K

Area of Science:

  • Orthopedic Surgery
  • Biomedical Engineering
  • Hand Surgery

Background:

  • Nonoperative treatment for thumb metacarpophalangeal (MCP) joint ulnar collateral ligament injuries (skier's thumb without Stener lesion) typically involves immobilization.
  • Thermoplastic splints are common for daily activities, offering custom comfort but are not suitable for sterile surgical environments.
  • A need exists for sterilizable splints to immobilize the thumb during surgical procedures.

Purpose of the Study:

  • To develop and describe a reusable, patient-specific splint for immobilizing the thumb MCP joint in a sterile surgical setting.
  • To enable an orthopedic surgeon to continue working despite a skier's thumb injury.

Main Methods:

  • Case presentation of a 36-year-old orthopedic surgeon with skier's thumb.
  • Development of a custom, reusable splint designed for sterile environments.
  • Application of the splint to immobilize the thumb MCP joint during surgical procedures.

Main Results:

  • A reusable, patient-specific splint was successfully developed and applied.
  • The splint effectively immobilized the thumb MCP joint in a sterile environment.
  • The orthopedic surgeon was able to continue performing surgical procedures.

Conclusions:

  • A novel, sterilizable, and reusable splint can be fabricated for patient-specific needs.
  • This innovation allows surgeons with skier's thumb to maintain surgical practice in sterile conditions.
  • This addresses a gap in available splinting options for orthopedic surgeons.