Continuing to work with a sterile thumb splint: A case report
Related Experiment Video
Updated: Feb 10, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
S Roner1, P Fürnstahl1, A Schweizer2
1Computer Assisted Research and Development Group, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.
Abstract:
Nonoperative treatment of an injured ulnar collateral ligament of the thumb metacarpophalangeal (MCP) joint (skier's thumb without a Stener lesion) is managed by immobilization. A splint is applied on the radial side with the thumb in slight flexion to immobilize the MCP joint and allow motion in the interphalangeal joint. Thermoplastic splints are mainly used for daily activities with the advantage of custom fabrication for optimal comfort. To immobilize the thumb during surgical procedures performed by an orthopedic surgeon, splints made of sterilizable materials are needed but not yet available to our knowledge. We present the case of a 36-year-old orthopedic surgeon diagnosed with skier's thumb, and the development and application of a reusable, patient-specific (i.e., the orthopedic surgeon) splint to immobilize the thumb MCP joint in a sterile environment so the surgeon could continue working.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Range Rule of Thumb to Interpret Standard Deviation
For instance, the range rule of thumb can be used to find the tallest and the shortest student in a class, given the mean student height and standard deviation. If the mean student height is 1.6 m and the standard deviation, s is 0.05 m, the height...
Data Reporting and Recording
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:

