Challenges of cold chain quality for routine EPI in south-west Burkina-Faso: An assessment using automated
1University of Ouagadougou, UFR SDS, Ouagadougou, Burkina Faso; Laboratoire Mixte International de Vaccinologie (LAMIVAC), Bobo-Dioulasso, Burkina Faso.
Background:
Abnormal temperatures are a major issue for vaccines within the Expanded Program of Immunization in tropical climates. Prolonged exposure to temperatures outside the standard +2 °C/+8 °C range can impact vaccine potency.
Methods:
The current study used automatic temperature recording devices (Testostore 171-1©) to monitor cold chain in remote areas of Western Burkina Faso. A series of 25 randomly selected health centers representing 33% of the existing 176 EPI facilities in Western Burkina Faso were prospectively assessed for eight months in 2015. Automatic measurements were compared to routine temperature loggers and vaccine vial monitors (VVM).
Results:
The median age for all refrigerators was 9 years with 10/25 (42%) older than 10 years. Adverse temperatures were recorded in 20/24 (83%) refrigerators and ranged from -18.5 °C to +34.2 °C with 12,958/128,905 (10%) abnormal hourly records below +2 °C and 7357/128,905 (5.7%) above +8 °C. Time of day significantly affected the rate of temperature excursions, with higher rates from 00 am to 06 am (p < 0.001) for low temperatures and 10-12 am (p < 0.001) and 13-16 pm (p < 0.001) for high temperatures. Abnormal temperatures lasted from 1 h to 24 h below +2 °C and 13-24 h above +8 °C. Standard manual registers reported only 182/2761 (7%) inadequate temperatures and VVM color change detected only 133/2465 (5%) disruptions. Reliability of the refrigerators ranged from 48% to 98.7% with a median of 70%. Risk factors for excursions were old age of the refrigerators, the months of April and May, hours of high activity during the day, and health staff-associated factors such as inappropriate actions or insufficient knowledge.
Conclusion:
Important cold chain reliability issues reported in the current study in Western Burkina Faso raise concern about vaccine potency. In the absence of systematic renewal of the cold chain infrastructure or improved staff training and monitoring, antibody response assessment is recommended to study levels of effective immunization coverage.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Responses to Heat and Cold Stress
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...