Feasibility of synthetic MRI in knee imaging in routine practice
Sana Boudabbous1, Angeliki Neroladaki1, Ilias Bagetakos1
1Department of Radiology, Geneva University Hospital, Geneva, Switzerland.
Background:
Synthetic magnetic resonance (MR) is a method allowing reduction of examination time and access to quantitative imaging.
Purpose:
This study sought to assess the image quality and diagnostic accuracy of synthetic magnetic resonance imaging (MRI) compared to standard MRI in patients with knee pain.
Material And Methods:
In total, 22 patients underwent standard 1.5 knee MRI with an added synthetic sequence. Quantitative T1, T2, and proton density (PD) images were generated synthetically; T1, PD, and short tau inversion recovery (STIR) weighted images were created with chosen echo time (TE), repetition time (TR), and inversion time (TI). Two blinded musculoskeletal radiologists evaluated the overall sequence quality, visualization of anatomic structures, and presence of artifacts using a 3-point score.
Results:
The synthetic sequence was acquired in 39% less time than the conventional MRI. Synthetic PD, T1, and STIR images were rated fair (2%, 5%, and 2%, respectively) or good quality (98%, 95%, and 98%, respectively), despite the presence of popliteal artery artifacts. Cartilage and meniscus were well visualized in all cases. Anterior cruciate ligament visualization was rated poor in 7%, 14%, and 30% of PD, STIR, and T1 images, respectively.
Conclusion:
Our pilot study confirmed the feasibility of synthetic MRI in knee examinations, proving faster and achieving appropriate quality and good diagnostic confidence.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Synthetic Biology
Golden rice
Golden rice is a genetically modified...
Synthetic Disvision of Polynomials
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...