Derivative estimation for longitudinal data analysis: Examining features of blood pressure measured repeatedly during
Andrew J Simpkin1,2, Maria Durban3, Debbie A Lawlor1,4
1MRC Integrative Epidemiology Unit at the University of Bristol, Bristol, BS8 2BN, UK.
Abstract:
Estimating velocity and acceleration trajectories allows novel inferences in the field of longitudinal data analysis, such as estimating change regions rather than change points, and testing group effects on nonlinear change in an outcome (ie, a nonlinear interaction). In this article, we develop derivative estimation for 2 standard approaches-polynomial mixed models and spline mixed models. We compare their performance with an established method-principal component analysis through conditional expectation through a simulation study. We then apply the methods to repeated blood pressure (BP) measurements in a UK cohort of pregnant women, where the goals of analysis are to (i) identify and estimate regions of BP change for each individual and (ii) investigate the association between parity and BP change at the population level. The penalized spline mixed model had the lowest bias in our simulation study, and we identified evidence for BP change regions in over 75% of pregnant women. Using mean velocity difference revealed differences in BP change between women in their first pregnancy compared with those who had at least 1 previous pregnancy. We recommend the use of penalized spline mixed models for derivative estimation in longitudinal data analysis.
Related Concept Videos
Measurement of Blood Pressure
Longitudinal Research
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...