Related Experiment Video
Updated: Feb 10, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Determination of cadmium in sediments by diluted HCI extraction and isotope dilution ICP-MS
Javier Terán-Baamonde1, Rosa-María Soto-Ferreiro1, Alatzne Carlosena1
1Grupo Química Analítica Aplicada (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Facultad de Ciencias, Universidade da Coruña, 15071 A Coruña, Spain.
Abstract:
Isotope dilution ICP-MS is proposed to measure the mass fraction of Cd extracted by diluted HCl in marine sediments, using a fast and simple extraction procedure based on ultrasonic probe agitation. The 111Cd isotope was added before the extraction to achieve isotope equilibration with native Cd solubilized from the sample. The parameters affecting trueness and precision of isotope ratio measurements were evaluated carefully and subsequently corrected in order to minimize errors; they were: detector dead time, spectral interferences, mass discrimination factor and optimum sample/spike ratio. The mass fraction of Cd extracted was compared with the sum of the certified contents of the three steps of the sequential extraction procedure of the Standards, Measurements and Testing Programme (SM&T) analysing the BCR 701 sediment to validate the method. The certified and measured values agreed, giving a measured / certified mass fraction ratio of 1.05. Further, the extraction procedure itself was studied by adding the enriched isotope after the extraction step, which allowed verifying that analyte losses occurred during this process. Two additional reference sediments with certified total cadmium contents were also analysed. The method provided very good precision (0.9%, RSD) and a low detection limit, 1.8 ng g-1. The procedural uncertainty budget was estimated following the EURACHEM Guide by means of the 'GUM Workbench' software, obtaining a relative expanded uncertainty of 1.5%. The procedure was applied to determine the bioaccessible mass fraction of Cd in sediments from two environmentally and economically important areas of Galicia (rias of Arousa and Vigo, NW of Spain).
More Related Videos
Related Concept Videos
Solution Concentration and Dilution
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Physiology of the Genitourinary System III: Urine Concentration and Dilution
Isotopes
An element's atomic mass, or weight,...
Elements: Chemical Symbols and Isotopes
Some symbols are derived from the common English name of the element; others are abbreviations of the name in another language — Latin, Greek or German. For example, the symbol for aluminum (common name)...
Isotopes and Radioisotopes
An isotope containing...

