Related Experiment Video
Updated: Feb 10, 2026

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
[CLINICAL OBSERVATION OF ROTATING-PLATFORM PROSTHESIS FOR VALGUS KNEE DEFORMITY]
Jian Gu1, Junying Sun1, Xijiang Zhao1
1Department of Orthopaedics, the First Affiliated Hospital of Soochow University, Suzhou Jiangsu, 215006, P. R. China.
Objective:
To investigate the effectiveness of rotating-platform prosthesis for valgus knee deformity in total knee arthroplasty (TKA).
Methods:
A retrospective analysis was made on the clinical date of 25 cases (28 knees) of valgus deformity undergoing primary TKA by using Gemini MK II rotating-platform prosthesis. There were 6 males (7 knees) and 19 females (21 knees), aged from 47 to 82 years, with an average age of 64.8 years. The unilateral knee was involved in 22 cases and the bilateral knees in 3 cases. The causes included osteoarthritis in 20 cases (22 knees), rheumatoid arthritis in 4 cases (5 knees), and traumatic arthritis in 1 case (1 knee). The disease duration was 2-22 years (mean, 10.4 years). The main clinical symptoms were arthralgia combined with limited movement. According to the Keblish grade, there were 13 knees of mild deformity, 11 knees of moderate deformity, and 4 knees of severe deformity.
Results:
All incisions healed by first intension. No complications of infection, cutaneous necrosis, deep venous thrombosis, and pulmonary embolism occurred. The postoperative follow-up duration was 12-60 months (mean, 25.4 months). Medial instability and palsies of nervus peroneus communis occurred in 1 and 2 cases respectively, and all were cured after symptomatic treatment. No patellar and polysthylene insert dislocation, prosthetic loosening or infection was observed. The Hospital for Special Surgery (HSS) score, femoral tibial angle, maximun flexion and extension angles, knee range of motion, and patellar score were significantly improved at last follow-up when compared with preoperative ones (P<0.01).
Conclusions:
The rotating-platform prosthesis for valgus deformity can obtain satisfactory effectiveness, but it requires precise soft tissue balancing technology, and the long-term effectiveness remains further observation.
More Related Videos
Related Concept Videos
Plastic Deformations
Plastic Deformations
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Temperature Dependent Deformation
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Naturalistic Observations