Related Experiment Video
Updated: Feb 10, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
[A biomechanical study on reconstruction of forearm interosseous membrane using extensor carpi radialis longus
Jianbang Guo1, Youming Zhao2, Xiaobin Li1
1Department of Orthopaedics, Traditional Chinese Medicine Hospital of Meizhou City. Meizhou Guangdong, 514000, P. R. China.
Objective:
To evaluate the effect of reconstruction of forearm interosseous membrane (IOM) using extensor carpi radialis longus combined with radial head replacement for restoring the forearm longitudinal stability.
Methods:
Ten fresh-frozen adult cadaveric forearms were selected, including 8 males and 2 females with a mean age of 38.2 years (range, 29-74 years). Each forearm was treated as following steps: radial head excision (group A), radial head excision+the distal ulnar radial joints separation (group B), radial head excision+the distal ulnar radial joints separation+IOM central band excision (group C), reconstructed IOM with extensor carpi radialis longus tendon (group D), radial head prothesis replacement (group E), and reconstructed IOM with extensor carpi radialis longus tendon+radial head prothesis replacement (group F). The distance between ulna and radius and radioulnar joint displacement were observed under load and non load. The force loading on both ends of specimen was recorded when the radius shifted 5 mm proximally.
Results:
Restoring the radial length could maintain normal distance between radius and ulna. The interosseous membrance reconstruction could restore the load transmission between radius and ulna. The force loading specimen was (74.507±4.967), (49.227±1.940), (17.827±1.496), (24.561±1.390), (140.247±8.029), and (158.423±9.142)N in groups A, B, C, D, E, and F respectively when the radius shifted 5 mm proximally, showing significant difference among groups (P<0.01).
Conclusions:
Reconstruction of the IOM with the extensor carpi radialis longus tendon is insufficient to restore the forearm longitudinal stability. Reconstruction using extensor carpi radialis longus tendon combined with radial head replacement may be a new choice for treatment of forearm longitudinal instability.
Related Concept Videos
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Longitudinal Studies
Longitudinal Research
Restorative Care
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...

