Multi-institutional study of the variability in target delineation for six targets commonly treated with radiosurgery
Helena Sandström1,2, Hidefumi Jokura3, Caroline Chung4
1a Medical Radiation Physics, Department of Physics , Stockholm University , Stockholm , Sweden.
Background:
Although accurate delineation of the target is a key factor of success in radiosurgery there are no consensus guidelines for target contouring.
Aim:
The aim of the present study was therefore to quantify the variability in target delineation and discuss the potential clinical implications, for six targets regarded as common in stereotactic radiosurgery.
Material And Methods:
Twelve Gamma Knife centers participated in the study by contouring the targets and organs at risks and performing the treatment plans. Analysis of target delineation variability was based on metrics defined based on agreement volumes derived from overlapping structures following a previously developed method. The 50% agreement volume (AV50), the common and the encompassing volumes as well as the Agreement Volume Index (AVI) were determined.
Results:
Results showed that the lowest AVI (0.16) was found for one of the analyzed metastases (range of delineated volumes 1.27-3.33 cm3). AVI for the other two metastases was 0.62 and 0.37, respectively. Corresponding AVIs for the cavernous sinus meningioma, pituitary adenoma and vestibular schwannoma were 0.22, 0.37 and 0.50.
Conclusions:
This study showed that the variability in the contouring was much higher than expected and therefore further work in standardizing the contouring practice in radiosurgery is warranted.
Related Concept Videos
Multi-input and Multi-variable systems
In the absence of...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Targets for Drug Action: Overview
Receptors are either membrane-spanning or intracellular proteins, which upon binding a ligand, get activated and transmit the signal downstream to elicit a response. Drugs bind receptors, either mimicking the action of endogenous ligands or blocking the receptor activity to bring about a modified response. Nearly 35% of approved drugs target the G...
Target Cell Response to Hormones
Notably, the cellular response can be regulated by altering the number of receptors expressed in the cell. For example, prolonged exposure to elevated hormone levels results in a gradual decline or down-regulation in the number of receptors for that specific hormone on the cell surface. Conversely, in response to low hormone levels, cells may use up-regulation, producing an...
Common Ion Effect
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...