Fluoroscopy-guided removal of individualised airway-covered stents for airway fistulas
Related Experiment Video
Updated: Feb 10, 2026

Imaging-Guided Bioreactor for Generating Bioengineered Airway Tissue
Published on: April 6, 2022
1Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Aim:
To report the techniques and complications associated with fluoroscopy-guided removal of individual covered stents for airway fistula disease over a 6-year period.
Materials And Methods:
A retrospective analysis was conducted of 85 patients, 72 male and 13 female, who underwent fluoroscopy-guided stent removal from January 2011 to June 2017. Patients ranged in age from 15 to 81 years (mean, 54.9±12.3 years). Before removal, 90 stents had been placed for airway fistula disease. All patients underwent diagnostic flexible bronchoscopy and airway computed tomography (CT) prior to stent removal. The indications for stent removal and post-interventional complications were analysed.
Results:
Eighty-nine of 90 airway stents were successfully removed from 85 consecutive patients, for a technique success rate of 98.9%. Of these, 14 stents showed strut fracture, one stent showed retained stent pieces, and the remaining 75 stents were removed in one piece. Indications for stent removal included regular removal (n=46), stent migration (n=11), excessive granulation tissue (n=10), strut fracture (n=4), intolerance of stenting (n=6). Complications of stent removal were as follows: retained stent pieces (n=1), mucosal tear with massive bleeding (n=2), re-obstruction requiring stenting (n=1), dyspnoea with mechanical ventilation needed (n=1), and dyspnoea with oxygen inhalation needed (n=1).
Conclusions:
Airway stents can be safely removed under fluoroscopy guidance. Removal after 31-90 days is recommended for removal to avoid excessive granulation tissue.
More Related Videos
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
10:18Real-Time, Semi-Automated Fluorescent Measurement of the Airway Surface Liquid pH of Primary Human Airway Epithelial Cells
Published on: June 13, 2019
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration