Objectives:
To develop an anthropomorphic phantom closely mimicking patient anatomy and to evaluate the phantom for the simulation of computed tomography (CT)-guided procedures.
Methods:
Patient CT images were printed with aqueous potassium iodide solution (1 g/mL) on paper. The printed paper sheets were stacked in alternation with 1-mm thick polyethylene foam layers, cut to the patient shape and glued together to create an anthropomorphic abdomen phantom. Ten interventional radiologists performed periradicular infiltration on the phantom and rated the phantom procedure regarding different aspects of suitability for simulating CT-guided procedures.
Results:
Radiopaque printing in combination with polyethylene foam layers achieved a phantom with detailed patient anatomy that allowed needle placement. CT-guided periradicular infiltration on the phantom was rated highly realistic for simulation of anatomy, needle navigation and overall course of the procedure. Haptics were rated as intermediately realistic. Participants strongly agreed that the phantom was suitable for training and learning purposes.
Conclusions:
A radiopaque 3D printed, anthropomorphic phantom provides a realistic platform for the simulation of CT-guided procedures. Future work will focus on application for training and procedure optimisation.
Key Points:
• Radiopaque 3D printing combined with polyethylene foam achieves patient phantoms for CT-guided procedures. • Radiopaque 3D printed, anthropomorphic phantoms allow realistic simulation of CT-guided procedures. • Realistic visual guidance is a key aspect in simulation of CT-guided procedures. • Three-dimensional printed phantoms provide a platform for training and optimisation of CT-guided procedures.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Blind Procedures
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...