Related Experiment Video
Updated: Feb 10, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Meniscal pathologies on MRI correlate with increased bone tracer uptake in SPECT/CT
Jan Rechsteiner1, Michael T Hirschmann1, Milos Dordevic1
1Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland Bruderholz, 4101, Binningen, Switzerland.
Objectives:
To assess the relationship of subchondral bone tracer uptake (BTU) on SPECT/CT and meniscal pathologies on MRI in patients with painful knees.
Methods:
Twenty-five patients who had MRI and SPECT/CT within 3 months without knee surgery or grade ≥3 cartilage lesions were prospectively included. Maximum values of each subchondral femorotibial area were quantified and a ratio was calculated in relation to a femoral shaft reference region, which represented the BTU background activity. Meniscal lesions were graded (intact/degeneration/tear) and meniscal extrusion (no/yes) was assessed using MRI by two musculoskeletal radiologists blinded to the SPECT/CT findings. One-tailed Spearman correlations served for statistics (p < 0.05).
Results:
Knees with meniscal degeneration or tear showed a significantly higher BTU in the medial femorotibial compartment (p = 0.045) when compared to intact menisci. Meniscal degeneration was associated with an increased BTU in the lateral femorotibial compartment; however, this was not statistically significant (p = 0.143). Patients with an extruded meniscus showed significantly higher BTU compared to a non-extruded meniscus (p < 0.020).
Conclusions:
Medial femorotibial BTU in SPECT/CT was associated with meniscal pathologies. Highest BTU was found in patients with meniscal tears. SPECT/CT appears to be a useful imaging modality to identify patients with overloading or early osteoarthritis.
Key Points:
• Meniscal degeneration and tears correlate significantly with increased BTU using SPECT/CT. • Medial meniscus extrusion is associated with an increased BTU in SPECT/CT. • SPECT/CT allows detection of overloading and early osteoarthritis.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlations
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Increasing Function
Increased Body Temperature