Methodology for Sputum Induction and Laboratory Processing
Published on: December 17, 2017
28.7K
Improvement of laboratory turnaround time using lean methodology.
Shradha Gupta1, Sahil Kapil2, Monica Sharma1
1Malaviya National Institute of Technology Jaipur, Jaipur, India.
Summary
Lean methodology significantly reduced clinical laboratory turnaround time (TAT) in an Indian hospital. This improves patient care, satisfaction, and hospital efficiency by streamlining processes and minimizing delays.
Area of Science:
- Healthcare Management
- Industrial Engineering
- Quality Improvement
Background:
- Delayed clinical laboratory reports impact patient diagnosis, waiting times, and satisfaction.
- Implementing industrial engineering principles in healthcare can enhance service efficiency.
Purpose of the Study:
- To implement lean methodology for reducing clinical laboratory turnaround time (TAT) in a super speciality hospital.
- To identify and address bottlenecks in laboratory processes to improve service delivery.
Main Methods:
- Utilized lean tools including Value Stream Mapping (VSM), Gemba, Pareto Analysis, and Root Cause Analysis.
- Conducted a four-month study involving hospital quality departments and laboratory staff.
Main Results:
- Identified 12 non-value-added factors in hematology and 5 in biochemistry labs.
- Reduced average TAT from 180 to 95 minutes (hematology) and 268 to 208 minutes (biochemistry).
Conclusions:
- Lean methodology offers a viable solution for improving efficiency and reducing TAT in Indian healthcare settings.
- Successful implementation of lean practices enhances service quality, patient satisfaction, and operational costs.
Related Concept Videos
Response Surface Methodology
674
Response Surface Methodology (RSM) is a collection of statistical and mathematical techniques used to develop, improve, and optimize processes. It is particularly valuable when many input variables or factors potentially influence a response variable.
The process of RSM involves several key steps:
The process of RSM involves several key steps:
674
Improving Translational Accuracy
3.7K
3.7K
Improving Translational Accuracy
15.0K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Systematic Error: Methodological and Sampling Errors
11.0K
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
11.0K
Serum Laboratory Studies, Stool Test, Breath Test
892
Gastrointestinal (GI) diagnostic studies are pivotal in confirming, ruling out, diagnosing, or staging various diseases, including cancers. Following diagnosis, allocating time for discussions with the patient and providing informational resources is crucial. Diagnostic assessments of the GI tract often occur in outpatient settings like endoscopy suites or GI labs. Preparation for these tests may include dietary restrictions, fasting, liquid bowel preparations, laxatives, enemas, and the...
892
Mixing Time
485
The concept of mixing time is significant in producing a uniform concrete mix with the required strength. The mixing period starts once all components are in the mixer. Initially, the mixer is charged with 10% of the water, followed by the consistent addition of solids and then 80% of the water. The remaining water is added later, within the first quarter of the mixing period. The minimum mixing time varies according to the mixer's capacity; for example, mixers with up to 1 cubic yard...
485