Abstract:
Intercostal artery injury during transthoracic puncture is rare but is accompanied by high rates of morbidity and mortality. We report a case with metachronous double primary esophageal cancers and development of multiple lung nodules. Tissue proof for the lung nodules is required to guide the following treatment protocol. Our patient died soon after computed tomography-guided lung tumor biopsy was performed, as a result of procedure-related massive and uncontrolled hemothorax. The cause is likely intercostal artery injury related to the transthoracic puncture. After review of our case and the wide variation in intercostal artery courses, we identify several considerations that should be included in procedural planning to further decrease the risk of intercostal artery injury during transthoracic puncture, including avoiding choosing target lesions at the posterior lung, keeping the puncture needle as close to the superior rib margin as possible, and checking the density of new pleural fluid. In addition, it is important to inform clinical doctors when the risk of periprocedural vascular injury is high.
More Related Videos
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
06:03Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Unusual Results
According to the range rule of thumb, any value above or below two standard deviations, 2σ from the mean, μ is considered unusual.
Maximum unusual value =...
Imaging Studies III: Computed Tomography
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Hemodialysis II: Procedure and Complications
Lung Capacity