Related Experiment Video
Updated: Feb 10, 2026

A "Patient-Like" Orthotopic Syngeneic Mouse Model of Hepatocellular Carcinoma Metastasis
Published on: October 24, 2015
Multi-Operational Selective Computer-Assisted Targeting of hepatocellular carcinoma-Evaluation of a novel approach
Pascale Tinguely1, Marius Schwalbe2, Torsten Fuss3
1Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Objective:
To facilitate precise local ablation of hepatocellular carcinoma (HCC) in a setting of combined ablation and transarterial chemoembolization (TACE), we evaluated accuracy and efficiency of a novel technique for navigated positioning of ablation probes using intrahepatic tumor referencing and electromagnetic (EM) guidance, in a porcine model.
Methods:
An angiographic wire with integrated EM reference sensor at its tip was inserted via a transarterial femoral access and positioned in the vicinity of artificial liver tumors. The resulting offset distance between the tumor center and the intrahepatic endovascular EM reference was calculated. Subsequently, EM tracked ablation probes were inserted percutaneously and navigated toward the tumor center, relying on continuous EM guidance via the intrahepatic reference. Targeting accuracy was assessed as the Euclidean distance between the tip of the ablation probe and the tumor center (Target Positioning Error, TPE). Procedural efficiency was assessed as time efforts for tumor referencing and tumor targeting.
Results:
In 6 animals, 124 targeting measurements were performed with an offset distance < 30 mm (clinically most feasible position), resulting in a mean TPE of 2.9 ± 1.6 mm. No significant correlation between the TPE and different intrahepatic offset distances (range 21 to 61 mm, n = 365) was shown as long as the EM reference was placed within the liver. However, the mean TPE increased when placing the EM reference externally on the animal skin (p < 0.01). TPE was similar when targeting under continuous ventilation or in apnea (p = 0.50). Mean time for tumor referencing and navigated targeting was 6.5 ± 3.8 minutes and 14 ± 8 seconds, respectively.
Conclusion:
The proposed technique allows precise and efficient navigated positioning of ablation probes into liver tumors in the animal model. We introduce a simple approach suitable for combined ablation and TACE of HCC in a single treatment session.
More Related Videos
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Real Number Operations
Operational Amplifiers
What is Natural Selection?
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...