Related Experiment Video
Updated: Feb 10, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Single-Acquisition Triple-Bolus Dual-Energy CT Protocol for Comprehensive Evaluation of Renal Masses: A Single-Center
Dinesh Manoharan1, Sanjay Sharma1, Chandan J Das1
11 Department of Radiology, All India Institute of Medical Science, New Delhi 110029, India.
Objective:
The primary objective of this study was to compare triple-bolus dual-energy CT (DECT) against standard triple-phase MDCT in terms of appropriateness of patient treatment.
Subjects And Methods:
One hundred twenty-four patients with suspected renal masses seen at ultrasound were randomized into triple-bolus DECT and triple-phase MDCT groups. Patients in the triple-bolus DECT group underwent synchronous corticomedullary nephrographic delayed-phase triple-bolus DECT. In the triple-phase MDCT group, single-energy triple-phase scans were acquired after an unenhanced scan. The primary outcome was appropriateness of treatment received at 1 year. The predefined noninferiority limit was 10%. Histopathologic analysis or follow-up confirmed the benign or malignant nature of the masses. Diagnostic accuracy to differentiate benign from malignant masses was calculated. Size-specific dose estimates were compared.
Results:
After excluding six patients, 118 patients were analyzed (62 triple-bolus DECT; 56 triple-phase MDCT). Treatment appropriateness was not significantly different (p = 0.9397) between the two groups (61/62 [98.39%; 95% CI, 95.26-101.52%] for triple-bolus DECT vs 55/56 [98.21%; 95% CI, 94.74-101.68%] for triple-phase MDCT). The absolute difference was 0.18% (95% CI, -4.48% to 4.84%). Both techniques had similar diagnostic accuracy (sensitivity, 98.25% vs 96.67%; specificity, 98.17% vs 97.97%). The mean (± SD) size-specific dose estimate was significantly lower for triple-bolus DECT than for triple-phase MDCT (19.02 ± 4.07 vs 57.04 ± 15.17 mGy; p < 0.0001).
Conclusion:
Single-acquisition triple-bolus DECT is noninferior to triple-phase MDCT, with similar diagnostic accuracy but delivering significantly less radiation.
Related Concept Videos
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Center of Mass: Introduction
Significance of Center of Mass
Applications of Integration to Find Centers of Mass
Equation of Motion: Center of Mass
Internal forces between any pair of particles manifest as collinear pairs of equal magnitude but opposite directions,...
Energy Basics

