Carbon monoxide analysis method in human blood by Airtight Gas Syringe - Gas Chromatography - Mass Spectrometry
1Forensic Toxicology and Chemistry Unit, University Centre of Legal Medicine Lausanne-Geneva, Chemin de la Vulliette 4, 1000 Lausanne, Switzerland; College of Health and Life Sciences, Department of Environmental Sciences, Brunel University London, Kingston Lane, Uxbridge, Middlesex UB8 3PH, United Kingdom.
Abstract:
Carbon monoxide is one of the most abundant toxic air pollutants. Symptoms of a CO intoxication are non-specific, leading to a high number of misdiagnosed CO poisoning cases that are missing in the disease statistics. The chemical nature of the molecule makes it difficult to detect for long periods and at low levels, thus requiring a very accurate and sensitive method. Current methods capable of accurate and sensitive analyses are available, however an inconsistency between results and symptoms are frequently reported. Therefore, an improved method for the analysis of carbon monoxide in blood and in the headspace (HS) of the sampling tube with the use of Airtight Gas Syringe - Gas Chromatography - Mass Spectrometry (AGS-GC-MS) is hereby presented and validated, for CO concentrations in a range of 10-200 nmol/mL HS (2-40 μmol/mL blood). Analytical LOQ is found at 0.9 nmol/mL HS (0.18 μmol/mL blood) and LOD at 0.1 nmol/mL gas. Application to intoxicated samples from autopsies and comparison to previously published methods show that this method is more appropriate, since performed under fully controlled conditions. Results show higher CO concentrations compared to previous approaches, indicating that results might have been underestimating the true blood CO burden. Therefore, this approach has the potential to help reduce the misdiagnosed cases and the gap between measurement and diagnosis of CO poisonings.
More Related Videos
08:15Metabolomic Analysis of Barley by Gas Chromatography/Mass Spectrometry
Published on: November 8, 2024
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Gas Exchange and Transport
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II