Related Experiment Video
Updated: Feb 10, 2026

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
An ultrasensitive and selective electrochemical aptasensor based on rGO-MWCNTs/Chitosan/carbon quantum dot for the
Behzad Rezaei1, Hamid Reza Jamei1, Ali Asghar Ensafi1
1Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 I.R., Iran.
Abstract:
An aptamer-based method is described for the electrochemical determination of lysozyme. A glassy carbon electrode was modified with a nanocomposite composed of reduced graphene oxide (rGO), multi-walled carbon nanotubes (MWCNTs), chitosan (CS), and a synthesized carbon quantum dot (CQD) from CS. The composition of the nanocomposite (rGO-MWCNT/CS/CQD) warrants a high surface-to-volume ratio, high conductivity, high stability, and great electrocatalytic activity. This nanocomposite provides a suitable site for better immobilization of aptamers due to the existence of many amino and carboxyl functional groups, and remaining oxygen-related defects properties in rGO. In addition, this nanocomposite allows considerable enhancement of the electrochemical signal and contributes to improving sensitivity. The amino-linked lysozyme aptamers were immobilized on the nanocomposite through covalent coupling between the amino groups of the aptamer and the amino groups of the nanocomposite using glutaraldehyde (GLA) linker. The modified electrode was characterized by electrochemical methods including differential pulse voltammetry (DPV), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). In the presence of lysozyme, the immobilized aptamer selectively caught the target lysozyme on the electrode interface that leads to a decrease in the DPV peak current and an increase in Charge Transfer Resistance (Rct) in EIS as an analytical signal. Using the obtained data from DPV and EIS techniques, two calibration curves were drawn. The anti-lysozyme aptasensor proposed has two very low LODs. These measures are 3.7 and 1.9 fmol L-1 within the wide detection ranges of 20 fmol L-1 to 10 nmol L-1, and 10 fmol L-1 to 100 nmol L-1 for DPV and EIS calibration curves, respectively. The GCE/rGO-MWCNT/CS/CQD showed sensitivity, high reproducibility, specificity and rapid response for lysozyme which can be used in biomedical fields.
More Related Videos
Related Concept Videos
Quantum Numbers
The Quantum-Mechanical Model of an Atom
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
The Carbon Cycle
Carbon Skeletons
The Dot Product