Motiva Ergonomix Round SilkSurface Silicone Breast Implants: Outcome Analysis of 100 Primary Breast Augmentations over 3 Years and Technical Considerations
Related Experiment Video
Updated: Feb 10, 2026

Long-term Culture of Human Breast Cancer Specimens and Their Analysis Using Optical Projection Tomography
Published on: July 29, 2011
Georg M Huemer1,2, Raphael Wenny1,2, Matthias M Aitzetmüller1,2
1Linz and Wels, Austria; and Munich, Germany.
Background:
Macrotextured anatomical implants are frequently used in aesthetic breast surgery; however, several safety concerns linked to this implant type have been raised recently. In an attempt to address these shortcomings, Motiva Ergonomix implants have been introduced. Here, the authors describe the current world's largest experience with these novel devices in aesthetic breast surgery and evaluate the postoperative outcome of 100 primary breast augmentations.
Methods:
A retrospective assessment of 100 consecutive primary breast augmentation patients over a period of 3 years was conducted. Patients were followed for a minimum of 6 months postoperatively. Demographics, surgical data, and complications were recorded. In addition, a survey regarding the breast augmentation outcome was performed.
Results:
The reasons for surgery were mainly hypoplasia (52 percent) and ptosis (28 percent). All implants were placed by means of an inframammary approach in a submuscular pocket, and the average implant volume was 370 cc (range, 150 to 700 cc) with mostly full projection (65 percent). The revision rate was 7 percent. The authors observed four cases of implant malpositioning, one implant rupture, one implant exchange for aesthetic reasons, and one hematoma evacuation. Nevertheless, the authors achieved a 100 percent satisfaction rate with the postsurgical outcome among both patients and surgeons.
Conclusions:
Motiva Ergonomix implants provide reliable and satisfying results for both patients and surgeons. They can be used safely and effectively for aesthetic breast surgery. However, like all breast prostheses, Motiva Ergonomix implants are not completely free of complications and should be used only with advanced technique to achieve optimal results.
Clinical Question/Level Of Evidence:
Therapeutic, IV.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Related Concept Videos
Design Consideration
The factor of safety is another key...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Transmission Line Design Considerations
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...