Related Experiment Video
Updated: Feb 10, 2026

A Reproducible Cartilage Impact Model to Generate Post-Traumatic Osteoarthritis in the Rabbit
Published on: November 21, 2023
The impact of conjunctival flap method and drainage cannula diameter on bleb survival in the rabbit model
Cooper D Rodgers1, Alissa M Meyer1, Nicole C Rosenberg1
1Department of Ophthalmology, University of Florida, Gainesville, Florida, United States of America.
Purpose:
To examine the effect of cannula diameter and conjunctival flap method on bleb survival in rabbits undergoing cannula-based glaucoma filtration surgery (GFS).
Methods:
Twelve New Zealand White rabbits underwent GFS in both eyes. The twenty-four eyes were divided into four groups. Two of the four groups (N = 12) received limbus-based conjunctival flaps (LBCF), and the other two (N = 12) received fornix-based conjunctival flaps (FBCF). Six FBCF rabbit eyes were implanted with 22-gauge drainage tubes, and the other six were implanted with 26-gauge tubes. Likewise, six LBCF rabbits received 22-gauge drainage tubes and six received 26-gauge tubes. Filtration blebs were evaluated every three days by a masked observer. Bleb failure was defined as the primary endpoint in this study and was recorded after two consecutive flat bleb evaluations.
Results:
Group 1 (LBCF, 22- gauge cannula) had a mean bleb survival time (Mean ± SD) of 18.7 ± 2.9 days. Group 2 (LBCF, 26-gauge cannula) also had a mean bleb survival time of 18.7 ± 2.9 days. Group 3 (FBCF, 22-gauge cannula) had a mean bleb survival time of 19.2 ± 3.8 days. Group 4 (FBCF, 26-gauge cannula) had a mean bleb survival time of 19.7 ± 4.1 days. A 2-way analysis of variance showed that neither surgical approach nor cannula gauge made a statistically significant difference in bleb survival time (P = 0.634 and P = 0.874). Additionally, there was no significant interaction between cannula gauge and conjunctival flap approach (P = 0.874), suggesting that there was not a combination of drainage gauge and conjunctival flap method that produced superior bleb survival.
Conclusion:
Limbus and fornix-based conjunctival flaps are equally effective in promoting bleb survival using both 22 and 26-gauge cannulas in the rabbit model. The 26-gauge drainage tube may be preferred because its smaller size facilitates the implantation process, reducing the risk of corneal contact.
More Related Videos
Related Concept Videos
Cell Motility through Blebbing
Blebbing Through the Matrix
In multicellular...
Parametric Survival Analysis: Weibull and Exponential Methods
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Survival Curves
The Kaplan-Meier estimator is the most common method for constructing survival curves. This...
Survival Tree
Building a Survival Tree
Constructing a...
Impact of Groups on Groups