Related Experiment Video
Updated: Feb 10, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Computer-based self-training for CT colonography with and without CAD
Lapo Sali1, Silvia Delsanto2, Daniela Sacchetto2
1Department of Biomedical, Experimental and Clinical Sciences "Mario Serio", University of Florence, Viale Morgani 50, 50134, Florence, Italy. lapo.sali@unifi.it.
Objectives:
To determine whether (1) computer-based self-training for CT colonography (CTC) improves interpretation performance of novice readers; (2) computer-aided detection (CAD) use during training affects learning.
Methods:
Institutional review board approval and patients' informed consent were obtained for all cases included in this study. Twenty readers (17 radiology residents, 3 radiologists) with no experience in CTC interpretation were recruited in three centres. After an introductory course, readers performed a baseline assessment test (37 cases) using CAD as second reader. Then they were randomized (1:1) to perform either a computer-based self-training (150 cases verified at colonoscopy) with CAD as second reader or the same training without CAD. The same assessment test was repeated after completion of the training programs. Main outcome was per lesion sensitivity (≥ 6 mm). A generalized estimating equation model was applied to evaluate readers' performance and the impact of CAD use during training.
Results:
After training, there was a significant improvement in average per lesion sensitivity in the unassisted phase, from 74% (356/480) to 83% (396/480) (p < 0.001), and in the CAD-assisted phase, from 83% (399/480) to 87% (417/480) (p = 0.021), but not in average per patient sensitivity, from 93% (390/420) to 94% (395/420) (p = 0.41), and specificity, from 81% (260/320) to 86% (276/320) (p = 0.15). No significant effect of CAD use during training was observed on per patient sensitivity and specificity, nor on per lesion sensitivity.
Conclusions:
A computer-based self-training program for CTC improves readers' per lesion sensitivity. CAD as second reader does not have a significant impact on learning if used during training.
Key Points:
• Computer-based self-training for CT colonography improves per lesion sensitivity of novice readers. • Self-training program does not increase per patient specificity of novice readers. • CAD used during training does not have significant impact on learning.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Weak Base Solutions

