Priming to protect maize from Fusarium verticillioides and its fumonisin accumulation
Ana Aguado1, Jean-Michel Savoie2, Sylvain Chéreau2
1IFAPA Las Torres Tomejil, Protección Vegetal Sostenible, Carretera Sevilla-Cazalla Km 12.2, Alcalá del Río, Seville, Spain.
Background:
Systemic infection through the seed is one of the routes used by the mycotoxinogenic pathogen Fusarium verticillioides for colonizing maize plants. The prohibition of the use of most chemical fungicides by the EU has promoted research on plant resistance inducers as an effective and sustainable alternative. Induction of a priming state in maize seeds might affect their susceptibility to contamination and accumulation of fumonisins. This state by application of a natural fertilizer called Chamae on maize seeds, was investigated in two varieties to control the colonization by the fungus and the accumulation of fumonisins B1 , B2 and B3 , germinating seeds, dead plants and yield.
Results:
After inoculation of F. verticillioides on germinating seeds, the colonization by the fungus and the accumulation of fumonisins were significantly lower in seedlings coming from treated seeds, but a significant number of plants stopped their development by necrosis. In a field trial, the 0.01% (v/v) application dilution showed a lower plant density, although the level of biomass at harvest was not affected.
Conclusion:
The priming state contributed to the control of F. verticillioides development from seed infection and fumonisin accumulation in the early stage of plant growth, without affecting the final crop yield, and could reduce fungicide use and environmental contamination. © 2018 Society of Chemical Industry.
Related Concept Videos
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Personal Protective Equipment


