Related Experiment Video
Updated: Feb 10, 2026

Estimating Virus Production Rates in Aquatic Systems
Published on: September 22, 2010
Comparison of five methods for the estimation of methane production from vented in vitro systems
Pablo S Alvarez Hess1, Richard J Eckard1, Joe L Jacobs2
1Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, Australia.
Background:
There are several methods for estimating methane production (MP) from feedstuffs in vented in vitro systems. One method (A; 'gold standard') measures methane proportions in the incubation bottle's headspace (HS) and in the vented gas collected in gas bags. Four other methods (B, C, D and E) measure methane proportion in a single gas sample from the HS. Method B assumes the same methane proportion in the vented gas as in the HS, method C assumes constant methane to carbon dioxide ratio, method D has been developed based on empirical data, and method E assumes constant individual venting volumes. This study aimed to compare the MP predictions from these methods to that of the gold standard method under different incubation scenarios, to validate these methods based on their concordance with a gold-standard method.
Results:
Methods C, D and E had greater concordance (0.85, 0.88 and 0.81), lower root-mean-square error (RMSE; 0.80, 0.72 and 0.85) and lower mean bias (0.20, 0.35, -0.35) with the gold standard than did method B (concordance 0.67, RMSE 1.49 and mean bias 1.26). Methods D and E were simpler to perform than method C, and method D was slightly more accurate than method E.
Conclusion:
Based on precision, accuracy and simplicity of implementation, it is recommended that, when method A cannot be used, methods D and E are preferred to estimate MP from vented in vitro systems. © 2018 Society of Chemical Industry.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Drug Product Performance: In Vitro–In Vivo Correlation
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Estimation of k and VD of Aminoglycosides

