HLA-G regulatory variants and haplotypes with susceptibility to recurrent pregnancy loss

N Yazdani1,2, M Shekari Khaniani2, M Bastami2

  • 1Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.

Related Concept Videos

Cis-regulatory Sequences02:02

Cis-regulatory Sequences

Cis-regulatory sequences are short fragments of non-coding DNA that are present on the same chromosomes as the genes that they regulate. These fragments serve as binding sites for transcriptional regulators, proteins that are responsible for controlling gene transcription and differential gene expression across cell types in eukaryotes. Cis-regulatory sequences can be close to the gene of interest or thousands of bases away in the DNA sequence; however, those sequences that are further away are...
11.9K
Cis-regulatory Sequences02:02

Cis-regulatory Sequences

4.2K
Histone Variants at the Centromere02:30

Histone Variants at the Centromere

Histone variants are the histone proteins with structural and sequence variations. These variants may be regarded as “mutant” forms that replace their canonical histone counterparts in the nucleosomes. Specific post-translational modifications on the histone variants enable further chromatin complexity and regulate tissue-specific gene expression. The most common histone variants are from histone H2A, H2B, and linker histone H1 families. However, several variants of histone H3...
5.1K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
392
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.4K