Characteristics of jugular bulb oxygen saturation in patients after cardiac arrest: A prospective study
E Wallin1, I-M Larsson1, J Nordmark-Grass1
1Department of Surgical Sciences - Anaesthesiology & Intensive Care, Uppsala University, Uppsala, Sweden.
Background:
Using cerebral oxygen venous saturation post-cardiac arrest (CA) is limited because of a small sample size and prior to establishment of target temperature management (TTM). We aimed to describe variations in jugular bulb oxygen saturation during intensive care in relation to neurological outcome at 6 months post- CA in cases where TTM 33°C was applied.
Method:
Prospective observational study in patients over 18 years, comatose immediately after resuscitation from CA. Patients were treated with TTM 33°C M and received a jugular bulb catheter within the first 26 hours post-CA. Neurological outcome was assessed at 6 months using the Cerebral Performance Categories (CPC) and dichotomized into good (CPC 1-2) and poor outcome (CPC 3-5).
Results:
Seventy-five patients were included and 37 (49%) patients survived with a good outcome at 6 months post-CA. No differences were found between patients with good outcome and poor outcome in jugular bulb oxygen saturation. Higher values were seen in differences in oxygen content between central venous oxygen saturation and jugular bulb oxygen saturation in patients with good outcome compared to patients with poor outcome at 6 hours (12 [8-21] vs 5 [-0.3 to 11]% P = .001) post-CA. Oxygen extraction fraction from the brain illustrated lower values in patients with poor outcome compared to patients with good outcome at 96 hours (14 [9-23] vs 31 [25-34]% P = .008).
Conclusions:
Oxygen delivery and extraction differed in patients with a good outcome compared to those with a poor outcome at single time points. Based on the present findings, the usefulness of jugular bulb oxygen saturation for prognostic purposes is uncertain in patients treated with TTM 33°C post-CA.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Specialized Characteristics of Cardiac Muscles
Cardiac muscle cells are smaller than skeletal muscles, averaging 10–20 mm in diameter and 50–100 mm in length. However, they have large energy demands for continuous contraction and relaxation. This energy is almost exclusively derived from aerobic metabolism of energy...
Solution Equilibrium and Saturation
Characteristics of Life
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Characteristics of Fluids