Related Experiment Video
Updated: Feb 10, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
[Effectiveness of acetabular revision using a metal reconstruction cage]
Zhenjun You1, Junying Sun2, Yi Jiang3
1Department of Orthopaedics, the First Hospital of Jiaxing, Jiaxing Zhejiang, 314000, P.R.China.zhenjun_110@163.com.
Objective:
To explore the clinical outcomes of acetabular revision using a metal reconstruction cage.
Methods:
Between October 2006 and October 2013, 16 patients (16 hips) underwent acetabular revision with a metal reconstruction cage. There were 4 males and 12 females, with the mean age of 62.7 years (range, 49-78 years). The time from total hip arthroplasty to revision was 3-15 years (mean, 8.2 years). The causes for revision were aseptic acetabular loosening in 15 cases, and femoral periprosthetic fracture (Vancouver type B3) in 1 case. According to the American Academy of Orthopaedic Surgeons (AAOS) classification, there were 12 cases of type III and 4 cases of type IV; according to the Paprosky classification, there were 12 cases of type IIIA and 4 cases of type IIIB. Harris score was used for hip function evaluation, and visual analogue scale (VAS) for pain in the thigh. X-ray films were taken for imaging evaluation.
Results:
Healing of incision by first intention was obtained in all patients. Deep venous thrombosis occurred in 1 patient, and was cured after anticoagulation therapy. No complications of infection, neurovascular injury, and prosthetic dislocation were found. Sixteen patients were followed up 6.8 years on average (range, 2-9 years). The Harris score was significantly increased from preoperative 42.44±4.66 to 91.88±3.28 at last follow-up ( t=-106.30, P=0.00). Two patients had mild pain in the thigh, but pain disappeared at 1 year after operation. At immediate after operation, the abduction angle was 37-54° (mean, 42.9°). The distance between acetabular rotation centre and teardrop line was (33.67±12.19) mm for preoperative value and was (20.67±9.63) mm for postoperative value, showing significant difference ( t=-9.60, P=0.00). The distance between acetabular rotation centre and lateral teardrop was (34.98±12.30) mm for preoperative value and was (40.04±6.61) mm for postoperative value, showing significant difference ( t=-3.15, P=0.00). X-ray film results showed bony fusion at the osteotomy sites at 4 to 12 months after operation. No continuous radiolucent line, prosthetic dislocation, or osteolysis was found, and bony ingrowth was observed in all patients. No patient received re-revision due to prosthetic loosening.
Conclusion:
The metal reconstruction cage for acetabular revision can achieve good effectiveness for patients with serious bone defect.
Related Concept Videos
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Alkali Metals
Table 1: Properties of the alkali metals
Properties of Transition Metals
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...

