Related Experiment Video
Updated: Feb 10, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Quantification of aortic stiffness in stroke patients using 4D flow MRI in comparison with transesophageal
Thomas Wehrum1, Felix Günther2, Miriam Kams3
1Department of Neurology and Clinical Neurophysiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany. thomas.wehrum@uniklinik-freiburg.de.
Abstract:
To quantify stiffness of the descending aorta (DAo) in stroke patients using 4D flow MRI and compare results with transesophageal echocardiography (TEE). 48 acute stroke patients undergoing 4D flow MRI and TEE were included. Intima-media-thickness (IMT) was measured in the DAo and the aorta was scrutinized for atherosclerotic plaques using TEE. Stiffness of the DAo was determined by (a) 4D flow MRI at 3 T by calculating pulse wave velocity (PWV) and by (b) TEE calculating arterial strain, stiffness index, and distensibility coefficient. Mean IMT was 1.43 ± 1.75. 7 (14.6%) subjects had no sign of atherosclerosis, 10 (20.8%) had IMT-thickening or plaques < 4 mm, and 31 (66.7%) had at least one large and/or complex plaque in the aorta. Increased IMT significantly correlated (p < 0.001) with increased DAo stiffness in MRI (PWV r = 0.66) and in TEE (strain r = 0.57, stiffness index r = 0.64, distensibility coefficient r = 0.57). Patients with at least IMT-thickening had significantly higher stiffness values compared to patients without atherosclerosis. However, no difference was observed between patients with plaques < 4 mm and patients with plaques ≥ 4 mm. PWV and TEE parameters of stiffness correlated significantly [strain (r = - 0.36; p = 0.011), stiffness index (r = 0.51; p = 0.002), and distensibility coefficient (r = - 0.59; p < 0.001)]. 4D flow MRI and TEE-based parameters of aortic stiffness were associated with markers of atherosclerosis such as IMT-thickness and presence of plaques. We believe that 4D flow MRI is a promising tool for future studies of aortic atherosclerosis, due to its longer coverage of the aorta and non-invasiveness.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Molecular Comparison of Gases, Liquids, and Solids
Evolutionary Relationships through Genome Comparisons
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...

