Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Speech Understanding in Noise for Adults With Cochlear Implants: Effects of Hearing Configuration, Source Location
René H Gifford1, Louise Loiselle2,3, Sarah Natale2
1Vanderbilt University Medical Center, Nashville, TN.
Purpose:
The primary purpose of this study was to assess speech understanding in quiet and in diffuse noise for adult cochlear implant (CI) recipients utilizing bimodal hearing or bilateral CIs. Our primary hypothesis was that bilateral CI recipients would demonstrate less effect of source azimuth in the bilateral CI condition due to symmetric interaural head shadow.
Method:
Sentence recognition was assessed for adult bilateral (n = 25) CI users and bimodal listeners (n = 12) in three conditions: (1) source location certainty regarding fixed target azimuth, (2) source location uncertainty regarding roving target azimuth, and (3) Condition 2 repeated, allowing listeners to turn their heads, as needed.
Results:
(a) Bilateral CI users exhibited relatively similar performance regardless of source azimuth in the bilateral CI condition; (b) bimodal listeners exhibited higher performance for speech directed to the better hearing ear even in the bimodal condition; (c) the unilateral, better ear condition yielded higher performance for speech presented to the better ear versus speech to the front or to the poorer ear; (d) source location certainty did not affect speech understanding performance; and (e) head turns did not improve performance. The results confirmed our hypothesis that bilateral CI users exhibited less effect of source azimuth than bimodal listeners. That is, they exhibited similar performance for speech recognition irrespective of source azimuth, whereas bimodal listeners exhibited significantly poorer performance with speech originating from the poorer hearing ear (typically the nonimplanted ear).
Conclusions:
Bilateral CI users overcame ear and source location effects observed for the bimodal listeners. Bilateral CI users have access to head shadow on both sides, whereas bimodal listeners generally have interaural asymmetry in both speech understanding and audible bandwidth limiting the head shadow benefit obtained from the poorer ear (generally the nonimplanted ear). In summary, we found that, in conditions with source location uncertainty and increased ecological validity, bilateral CI performance was superior to bimodal listening.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
03:49Author Spotlight: Optimizing EAS with Long Electrodes for Enhanced Cochlear Coverage and Hearing Preservation
Published on: October 11, 2024
Related Concept Videos
Hearing
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Understanding the Self
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...