Related Experiment Video
Updated: Feb 10, 2026

Testing the Efficacy of Pharmacological Agents in a Pericardial Target Delivery Model in the Swine
Published on: July 7, 2016
Pericardial Patch Augmentation Is Associated With a Higher Risk of Recurrent Aortic Insufficiency
Eilon Ram1, Yaron Moshkovitz2, Ami Shinfeld1
1Department of Cardiac Surgery, Leviev Cardiothoracic and Vascular Center, Sheba Medical Center at Tel Hashomer, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Background:
This study assessed early and late clinical outcomes in patients who underwent aortic valve repair or an aortic valve-sparing operation and investigated predictors for failure.
Methods:
Of 227 consecutive patients who underwent aortic valve repair or a valve-sparing operation in our department between 2004 and 2016, 81 (36%) underwent aortic root replacement with or without cusp repair, 97 (42%) ascending aorta replacement with or without cusp repair, and 49 (22%) isolated aortic valve repair. Clinical and echocardiographic follow-up was complete.
Results:
One patient (0.4%) died in-hospital. Mean clinical and echocardiographic follow-up was 69 ± 40 months (range, 1 to 147 months) and 53 ± 40 months (range, 1 to 147 months), respectively. Fifteen patients (6.6%) died during follow-up, with an overall 5-year survival rate of 94.4%. Recurrent significant (≥3) aortic insufficiency developed in 20 patients (8.8%), 17 of whom underwent reoperation, with a 5-year freedom from reoperation rate of 88%. Predictors for recurrent significant aortic insufficiency or reoperation were greater preoperative aortic insufficiency (grade III to IV vs I to II; relative risk [RR], 1.97; p = 0.023), cusp repair (RR, 2.92; p = 0.001), higher European System for Cardiac Operative Risk Evaluation score (RR, 1.16; p = 0.006), and valve repair with pericardial patch augmentation (RR, 2.34; p = 0.032).
Conclusions:
Aortic valve repair and valve-sparing operations can be performed with good early and late clinical outcomes. In our experience, however, the rate of recurrent aortic insufficiency was significant, especially in patients who underwent cusp augmentation with glutaraldehyde-treated autologous pericardial patch.
More Related Videos
Related Concept Videos
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Long-patch Base Excision Repair
Relative Risk
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Aortic Regurgitation I: Introduction